Evaluation unit CES-AZ-ABS-01B (for 1 read head)
- 1 read head can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact / NO contact per safety contact
- Unicode evaluation unit
- Category 3 / PL e according to EN ISO 13849-1

Açıklama
Unicode evaluation unit
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Max. 8 actuators can be taught-in.
Guard lock monitoring
Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories
Category according to EN ISO 13849-1
Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
- Category 3 / PL e according to EN ISO 13849-1
To achieve the stated category, both safety contacts must always be evaluated.
Actuating range
The evaluation unit has the standard actuating range, which allows for greater tolerances in the alignment of the read head and actuator, for example.
Where a smaller actuating range is required, the version with reduced actuating range (CES-A-...-01) can be used.
Additional connections
TST | Input for self-test |
OUT | Monitoring output (semiconductor) |
ERR | Diagnostic output |
GND | Connected internally to 0V (not for high currents) |


Dimensional drawings

1 | Suitable for 35 mm mounting rail according to EN 60715 |
Connection examples

Teknik Veriler
Approvals


Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | max. 10 % |
Operating and display elements
LED display | |
Status LED | |
Diagnostics LED | |
Safety contacts status |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
Connection cross section | |
Screw terminals | 0.25 ... 2.5 mm² |
Operating voltage DC | |
UB | 21 ... 24 ... 27 V DC regulated, residual ripple<5% |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Current consumption | |
(with relay energized) | 150 mA (without taking into account the load currents at the monitoring outputs) |
Degree of contamination (external, according to EN 60947-1) | 2 |
Inputs: test input TST | |
Input voltage | |
HIGH | 15 ... UB V DC |
LOW | 0 ... 2 V DC |
Monitoring outputs: diagnostics ERR, door monitoring output OUT | |
Output type | Semiconductor output, p-switching |
Output voltage | 0.8 x UB ... UB V DC |
Output current | max. 20 mA |
Safety contacts 13/14, 23/24 | |
Fuse | |
external (safety circuit) according to EN 60269-1 | 6 AgG or 6 A circuit breaker (characteristic B or C) |
Output type | Relay contacts, floating |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Discrepancy time | |
(between the operating points of both relays) | max. 25 ms |
Utilization category | |
AC-15 | 230 V 2 A |
AC-12 | 60 V 0.3 A |
AC-12 | 30 V 6 A |
DC-12 | 60 V 0.3 A |
DC-12 | 30 V 6 A |
DC-13 | 24 V 3 A |
Switching load | |
according to c UL us | Class 2 max. 30 V AC / Class 2 max. 60V DC |
Switching current | |
at switching voltage AC 5 ... 230 V | 10 ... 2000 mA |
at switching voltage AC/DC 5 ... 30 V | 10 ... 6000 mA |
at switching voltage AC/DC 21 ... 60 V | 1 ... 300 mA |
Mechanical values and environment
Connection type | plug-in screw terminals, coded |
Number of read heads | 1 read head can be connected |
Ready delay | max. 3 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set to LOW level during the ready delay.) |
Switching frequency | max. 1 Hz (If the current load is>100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.) |
Atmospheric humidity | |
not condensing | max. 80 % rH |
Mounting distance | |
between evaluation units | min. 10 mm |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Response time | |
after change in the actuation status | max. 180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of an actuator.) |
Degree of protection | IP20 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Dwell time | min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).) |
Material | |
Housing | Plastic PA6.6 |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 Relay with internally monitored contacts |
Mechanical life | |
Operating cycles (relay) | 10 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Number of switching cycles | |
≤ 1 A at 24 V DC | max. 153000 1/y |
≤ 0.1 A at 24 V DC | max. 760000 1/y |
≤ 3 A at 24 V DC | max. 34600 1/y |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Monitoring of the guard position | |
Diagnostic Coverage (DC) | 90 % |
Category | 3 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 4.3 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measure. |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s | |
Minimum distance | min. 1.2 mm |
Switch-on distance | |
with center offset m=0 | 5 mm (These values apply to surface installation of the read head in steel.) |
Secured switch-off distance sar | max. 10 mm |
Secured switching distance sao | |
with center offset m=0 | min. 3.5 mm (These values apply to surface installation of the read head in steel.) |
Switching hysteresis | 0.1 ... 0.3 mm (These values apply to surface installation of the read head in steel.) |
In combination with read head CES-A-LMN-SC
Mounting distance | |
between read heads | min. 20 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
Minimum distance for side approach direction | min. 3 mm |
Switch-on distance | |
with center offset m=0 | 15 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 26 mm |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | 0.5 ... 2 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LQA-SC
Mounting distance | |
between read heads | min. 80 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Switch-on distance | |
for vertical approach direction (center offset m=0) | 15 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 8 mm) | +/- 22 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 47 mm |
Secured switching distance sao | |
for vertical approach direction (center offset m=0) | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 8 mm) | min. +/- 18 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
for side approach direction (distance in x direction 8 mm) | 1 ... 1.8 mm (These values apply to surface installation of the read head and the actuator.) |
for vertical approach direction (center offset m=0) | 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance | |
between read heads | min. 50 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm (on mounting in non-metallic environment) |
Switch-on distance | |
with center offset m=0 | 16 mm (on mounting in non-metallic environment) |
Secured switch-off distance sar | max. 33 mm |
Secured switching distance sao | |
with center offset m=0 | min. 11 mm (on mounting in non-metallic environment) |
Switching hysteresis | 0.5 ... 2 mm (on mounting in non-metallic environment) |
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Switch-on distance | |
for vertical approach direction (center offset m=0) | 23 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 10 mm) | +/- 28 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 60 mm |
Secured switching distance sao | |
for vertical approach direction (center offset m=0) | min. 16 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 10 mm) | min. +/- 24 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
for vertical approach direction (center offset m=0) | 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 10 mm) | 1 ... 1.3 mm (These values apply to surface installation of the read head and the actuator.) |
Aksesuar

CEM-A-LE05K-S2
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included

CEM-A-LE05K-S1-10P
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- CES evaluation unit connection: 10 m cable, PUR
- Connection for solenoid operating voltage: M8 male plug
- Up to category 4 according to EN ISO 13849-1
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler







Diğer Belgeler



CAD Verileri
Sipariş verileri
Sip. No. | 100064 |
Makale adı | CES-AZ-ABS-01B |
Ağırlık | 0,244kg |
Global Trade Item Number (GTIN) | 4047048005594 |
Gümrük sınıfı | 85364110 |
ECLASS | 27-27-24-03 Safety-related transponder switch |