CET1-AX-LRA-00-50L-SA (Sip. No. 104062)

Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs

  • Read head with guard locking
  • Locking force up to 6500 N
  • Category 4 / PL e according to EN ISO 13849-1
  • With plug connector M12
  • 2 LEDs (2 freely configurable)
  • Approach direction A (delivery state)
CET1-AX-LRA-00-50L-SA (Sip. No. 104062)

Açıklama

Combination options

Suitable for connection to a CES-AZ evaluation unit

Approach direction

Horizontal

Can be adjusted in 90° steps

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET1

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

LED function display

LED red

freely configurable

LED green

freely configurable

Notes

  • Special connecting cables from EUCHNER are required for the connection. Please take into account in the order!
  • The device may be operated only in conjunction with the actuator CET-A-.... The actuator must be ordered separately.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Plug connector M12 8-pin, not aligned

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/5

Electrical connection values

Power consumption
Solenoid 11 W
Rated insulation voltage Ui 50 V
Rated impulse voltage Uimp 1.5 kV
Operating voltage DC
LED 24 V DC -15% ... +15% reverse polarity protected
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Safety class III
Current consumption
ICM 450 mA Solenoid
LED max. 6 mA
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M12, 8-pin
Installation orientation any
Switching frequency 1 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (with screwed tight plug connector)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,9 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 104062
Makale adı CET1-AX-LRA-00-50L-SA
Ağırlık 1,15kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking