TQ1-1202SG024-5000 (Sip. No. 104748)

Safety switch TQ, connection cable, connecting cable 5m

  • Connecting cable, 5 m
  • Auxiliary release from 3 sides
  • Switching element 1202S
  • LED indicator
  • Closed-circuit current principle
TQ1-1202SG024-5000 (Sip. No. 104748)

Açıklama

Approach direction

Vertical

Guard locking principle

closed-circuit current (power to unlock): In a safety guard with guard locking according to the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with current. The guard is unlocked by means of magnetic force. This is also referred to as mechanical guard locking.

Guard locking for process protection

The safety switch meets the requirements for interlocking devices with guard locking for process protection. It has no safety monitoring of the guard locking.

Switching element

1202S

Slow-action switching contact

Contacts for guard locking: 2 NC contacts

Contacts for door monitoring: 2 positively driven, positively driven contacts 1 NO contact

LED indicator

The LED indicator illuminates when voltage is applied to the guard locking solenoid.

Auxiliary release with triangular wedge

The auxiliary release allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).

Scope of delivery

Triangular key for manual release is included in the scope of delivery.

Required accessories

Actuator is not included in the scope of delivery.

Dimension drawing
Dimension drawing
Wiring diagram 1202S
Wiring diagram 1202S

Dimensional drawings

Dimensional drawings
1Triangular key

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20TÜV Süd München_B 40393 0023c_UL_us_E93776_9

Electrical connection values

Power consumption 2.7 W
Rated insulation voltage Ui 300 V
Rated impulse voltage Uimp 2.5 kV
Utilization category
AC-15 Safety contact 0.75 A 250 V
AC-15 Monitoring contact 1 A 125 V
DC-13 Monitoring contact 0.22 A 125 V
DC-13 Safety contact 0.27 A 250 V
Short circuit protection according to IEC 60269-1 2A gG
Solenoid operating voltage
DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 2.5 A

Mechanical values and environment

Approach speed 3 ... 60 m/min
Connection type Connecting cable, 5 m
Number of guard lock monitoring NC contacts 2
Number of door position NO contacts 1
Number of door position positively driven contacts 2
Extraction force 10 N
Actuation frequency max. 900 1/h
Actuating force 5 N
Installation orientation any
Insertion depth 26.3 mm
Mechanical life 1 x 10⁶
Retention force 1 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +50 °C
Material
Housing Reinforced thermoplastic
Contact Silver alloy, gold flashed
Locking force Fmax 500 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position2x10620 y
Important! Values valid for DC-12 100 mA/24V


In combination with actuator ACTUATOR-Q-WTB

Horizontal overtravel 1.3 mm

In combination with actuator ACTUATOR-Q-GT, HINGED ACTUATOR-Q-RO, HINGED ACTUATOR-Q-LU, ACTUATOR-Q-WT

Horizontal overtravel 1.9 mm

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 3,8 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 104748
Makale adı TQ1-1202SG024-5000
Ağırlık 0,591kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control