EUCHNER – More than safety.
EUCHNER – More than safety.

CET2-AX-LRA-00-50X-SA (Sip. No. 106039)

Read head CET2-AX-... M12, with guard locking and guard lock monitoring

  • Read head with guard locking
  • Locking force up to 6500 N
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector M12
  • 2 LEDs (1 freely configurable)
  • Approach direction A (delivery state)
CET2-AX-LRA-00-50X-SA (Sip. No. 106039)

Açıklama

Combination options

Suitable for connection to a CES-AZ evaluation unit

Approach direction

Horizontal

Can be adjusted in 90° steps

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET2

Open-circuit current principle, guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid.

LED function display

LED red

illuminates when solenoid is switched on

LED green

freely configurable

Category according to EN ISO 13849-1

Important: The category according to EN ISO 13849-1 depends on the evaluation unit used and on the installation orientation.

Notes

  • Special connecting cables from EUCHNER are required for the connection. Please take into account in the order!
  • The device may be operated only in conjunction with the actuator CET-A-.... The actuator must be ordered separately.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Plug connector M12 8-pin, not aligned

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/5DGUV_ET 20018_ET 20019

Electrical connection values

Power consumption
Solenoid 11 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
LED 24 V DC -15% ... +15% reverse polarity protected
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Safety class
EN IEC 61140 III
Current consumption
ICM 450 mA Solenoid
LED max. 6 mA
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M12, 8-pin
Installation orientation any
Switching frequency 1 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (with screwed tight plug connector)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Open-circuit current principle

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,9 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 106039
Makale adı CET2-AX-LRA-00-50X-SA
Ağırlık 1,166kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.