Non-contact safety switch CES-AR-CL2-..., with flying lead, PUR
- Safety switch with integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge left
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PUR, 5 m, flying lead, 8-core
- Unicode
- Two safety screws M4x14 included
Açıklama
Short circuit monitoring
The switch generates its own clock signal on the output lines OA/OB.
Pay attention to this aspect when connecting to control systems and relays.
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Typical actuating range
(actuator CES-A-BLN... in conjunction with safety switch CES-AR-C.2-... in case of mounting on plastic)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the substrate material and installation situation.
Terminal assignment
Designation | Function | Connecting cable conductor coloring |
---|---|---|
IB | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
OA | Safety output, channel 1 | GN |
OB | Safety output, channel 2 | YE |
OUT | Monitoring output | GY |
IA | Enable input for channel 1 | PK |
0 V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Dimensional drawings
1 | Active face |
2 | Fastening lug with reinforcement plate |
3 | LED status indication |
4 | Active face |
Connection examples
Teknik Veriler
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple<5% |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Current consumption | max. 50 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(OA,OB) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
LOW U(OA,OB) | 0 ... 1 V DC |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 200 mA |
Test pulse duration | max. 1 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 140 ms |
Mechanical values and environment
Connection type | Connecting cable PUR, length 5 m |
Tightening torque | |
Fixing screws | max. 1 Nm |
Ready delay | 10 s |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between switches | min. 120 mm |
Mounting type | non-flush on metal |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67/IP69K |
Cable ambient temperature (dynamic) | -25 ... +65 °C |
Cable ambient temperature (static) | -30 ... +65 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 1.9x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710
Switch-on distance | 15 mm |
Secured switch-off distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Secured switching distance sao | min. 10 mm |
Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BDN-06-104730
Switch-on distance | 19 mm |
Secured switch-off distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Secured switching distance sao | min. 14 mm |
Switching hysteresis | 1 ... 2 mm |
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Diğer Belgeler
CAD Verileri
Sipariş verileri
Sip. No. | 109047 |
Makale adı | CES-AR-CL2-AH-L05-109047 |
Ağırlık | 0,245kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |