EUCHNER – More than safety.
EUCHNER – More than safety.

ZSB2A4S06A-C2302 (Sip. No. 109470)

ZSB, housing G1, 3-stage, 1 pushbutton and 1 LED, cable

  • Housing G1
  • 3-stage function
  • Coiled connecting cable, 7.2 m
  • 1 LED and 1 pushbutton
ZSB2A4S06A-C2302 (Sip. No. 109470)

Açıklama

Switching element

220

2 NO + 2 NC

Cable

The high quality connecting cables (individual screening of the safety contacts) are available coiled.

3-stage function

Enabling function is active only in the second stage (center position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).

Dimension drawing
Dimension drawing
Wiring diagram 220 with 1 pushbutton and 1 LED
Wiring diagram 220 with 1 pushbutton and 1 LED
Travel diagram
Travel diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Shift travel diagrams

Shift travel diagrams
closed, enabling
closed
open

Teknik Veriler

Approvals

CCC2020980305002418_CQC2009010305380679_2024EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_4/2

Operating and display elements

ItemColorExtrasVersionSwitching elementSlide-in labelNote slide-in labelNumberDesignation1LED
gnLED
Pushbutton

Electrical connection values

Connecting cable 8x0.5 mm² + 8x0.14 mm² (4x0.5 mm² screened + 4x0.5 mm² unscreened + 8x0.14 mm² unscreened. Outer screen over everything.)
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 0.8 kV
Utilization category
AC-15 2 A 24 V
DC-13 2 A 24 V
Short circuit protection according to IEC 60269-1
at 24V 2A gG
Switching voltage
min. at 10 mA min. 12 V
Switching current
min. at 24 V min. 1 mA
Degree of contamination (external, according to EN 60947-1) 3
Display/control element
Utilization category
AC-15 Additional elements 400 mA 24 V
DC-13 Additional elements 100 mA 24 V
Short circuit protection according to IEC 60269-1
Additional elements at 24V 0.1A gG

Mechanical values and environment

Connection type flying lead
Number of NO contacts 2
Number of positively driven contacts 2
Cable length
coiled 7.2 m
Mechanical life
Position 1-2-3-1 0.1 x 10⁶
Position 1-2-1 0.1 x 10⁶
Switching principle Slow-action contact element
Degree of protection IP65
Ambient temperature -5 ... +50 °C
Material
Housing Plastic, black
Cap Elastomer, low PAH, black

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch
B10D 0.5 x 10⁶

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 1,8 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 109470
Makale adı ZSB2A4S06A-C2302
Ağırlık 2,111kg
Gümrük sınıfı 85371098
ECLASS 27-37-12-38 Agreement switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.