CET3-AP-CRA-AH-50X-SI-C2354-113141 (Sip. No. 113141)

Non-contact safety switch CET-AP-..., without auxiliary release, with escape release, for connection to decentralized peripheral systems

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Without auxiliary release
  • With 2 plug connectors M12
  • Unicode
  • Indication of the door position by LED
  • Approach direction A (delivery state)
CET3-AP-CRA-AH-50X-SI-C2354-113141 (Sip. No. 113141)

Açıklama

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switch

The device may be operated only in conjunction with the actuator CET-A-....

Important: The actuator must be ordered separately.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

LED function display

State LED

Status LED

DIA LED

Diagnostics LED

LED 1 rd

illuminates when the solenoid is energized

LED 2 gn

illuminates when door is closed

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

Connector assignment

Plug connector (view of connection side)PinDesignationFunction

X 1.1UBBOperating voltage, 24 V DC
X 1.2OAOutput A
X 1.30 VGND
X 1.4OBOutput B
X 1.5-n.c.
X 2.1-n.c.
X 2.2-n.c.
X 2.30V UCMSolenoid, 0 V
X 2.4+UCMOperating voltage of solenoid 24 V DC
X 2.5-n.c.
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram
CET: Transponder-coded safety switch with guard locking in use
CET3-AP: Mounting emergency release safety swith CET3-AP
CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle)
CET3-AP: Mounting auxiliary release with key CET3-AP

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage UCM) 0.5 ... 8 A
Power consumption
Solenoid 11 W
Connecting cable 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7))
Operating voltage DC
LED 24 V DC -15% V DC ... +10% V DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Switching load
according to UL 24V DC, Class 2 (For alternatives, see operating instructions)
Safety class III
Current consumption
IB 80 mA
ICM 450 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Ready delay 1 s
Installation orientation any
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (When inserted and secured)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-3.1x10-9420 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

C number
C2354 Blind plug for auxiliary release
Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 9,8 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 113141
Makale adı CET3-AP-CRA-AH-50X-SI-C2354-113141
Ağırlık 1,247kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking