Locking set MGB-L2...-PN... (guard locking by solenoid force) with 4 control elements, push-pull plug, RC12
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 illuminated pushbuttons with symbol
- Push-pull plug
- including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Multicode
Açıklama
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Dimensional drawings
Teknik Veriler
Approvals
Handle modules MGB-H-AA1A6-R-111838 (Order no. 111838)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate and automatic lockout mechanism |
Locking modules MGB-L2B-PNC-R-117024 (Order no. 117024)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
L0 | |
B1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | white | printed | 1NO | Illuminated pushbutton | |||||
91 | Yellow | printed | 1NO | Illuminated pushbutton | |||||
92 | Blue | printed | 1NO | Illuminated pushbutton | |||||
94 | with adhesive ring | 2 PD | Emergency stop illuminated |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Multicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Mechanical values and environment
Connection type | |
for enabling switch | Plug connector RC12 (X14) |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
Push-pull power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Enabling switch | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Enabling switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Miscellaneous
Product version number | V3.30.11 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Bileşenler
111838
MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
117024
MGB-L2B-PNC-R-117024
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 4 control elements, push-pull plug, RC12
MGB-L2B-PNC-R-117024
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 4 control elements, push-pull plug, RC12
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 illuminated pushbuttons with symbol
- Push-pull plug
- including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Multicode
Aksesuar
Spare parts
ZSA
ZSA, 3-stage, with cable and plug connector RC12
092141
ZSA092141C2038
ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch
097567
ZSA097567C2038
ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch
099495
ZSA099495C2038
ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch
100873
ZSA100873C2038
ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2123624
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
UKCA-Konformitätserklärung
Dok. No.
EDC20001506
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Diğer Belgeler
Application examples
Approvals and certificates
DGUV
Dok. No.
Versiyon
Dil
Boyut
DGUV
Dok. No.
Versiyon
Dil
Boyut
0,8 MB
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
0,2 MB
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
0,2 MB
TUEV Süd München M6A Zertifikat
Dok. No.
Versiyon
Dil
Boyut
TUEV Süd München M6A Zertifikat
Dok. No.
Versiyon
Dil
Boyut
0,3 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
0,7 MB
CAD Verileri
Sipariş verileri
Sip. No. | 117025 |
Makale adı | MGB-L2HB-PNC-R-117025 |
Ağırlık | 5,72kg |
Gümrük sınıfı | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |