Control panel MGB-...-PN with 11 controls and indicators, 7/8" and M12 plugs, RC12
- Control panel
- Emergency stop according to ISO 13850, illuminated
- 9 illuminated pushbuttons
- Operating mode selector
- Connection via 7/8" and M12 plugs
- including terminal plug for stack light (M12, 5-pin)
- including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
Açıklama
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Dimensional drawings
Teknik Veriler
Approvals
Operating and display elements
Occupancy diagram | |
C1 | |
B2 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
10 | white | 1NO | Illuminated pushbutton | ||||||
11 | white | 1NO | Illuminated pushbutton | ||||||
12 | Green | printed | 1NO | Illuminated pushbutton | |||||
13 | 2 PD | Emergency stop illuminated | |||||||
14 | white | printed | 1NO | Illuminated pushbutton | |||||
15 | Yellow | printed | 1NO | Illuminated pushbutton | |||||
16 | white | 1NO | Illuminated pushbutton | ||||||
17 | white | 1NO | Illuminated pushbutton | ||||||
90 | white | printed | 1NO | Illuminated pushbutton | |||||
91 | Code 2 of 3 | O ; I | Operating mode selector | ||||||
92 | Blue | printed | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
for enabling switch | Plug connector RC12 (X14) |
for Stacklight | Plug connector M12 (X6) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
Installation orientation | any |
Switching frequency | 0.25 Hz |
Response time | |
Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Enabling switch | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Diagnostic Coverage (DC) | 99 % |
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Safe multi-position switch | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc. |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Miscellaneous
Product version number | V3.30.10 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Aksesuar
ZSA
ZSA, 3-stage, with cable and plug connector RC12
092141
ZSA092141C2038
ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch
097567
ZSA097567C2038
ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch
099495
ZSA099495C2038
ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch
100873
ZSA100873C2038
ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2123624
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
UKCA-Konformitätserklärung
Dok. No.
EDC20001506
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Diğer Belgeler
Sipariş verileri
Sip. No. | 124822 |
Makale adı | MGB-CB-PN-124822 |
Ağırlık | 3,407kg |
Gümrük sınıfı | 85371098 |