Locking set MGB-L2...-PN... (guard locking by solenoid force) with 2 control elements, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode
Açıklama
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Dimensional drawings
Teknik Veriler
Approvals
Handle modules MGB-H-AA1A2-R-106049 (Order no. 106049)
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate |
Locking modules MGB-L2B-PNA-L-125577 (Order no. 125577)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
L0 | |
B1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | 1NO | Illuminated pushbutton | |||||||
95 | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Miscellaneous
Slide-in label | |||||||
| |||||||
Product version number | V3.30.10 | ||||||
Additional feature | incl. lens set, ID no. 120344 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Bileşenler
106049
MGB-H-AA1A2-R-106049
Handle module MGB-H-...
MGB-H-AA1A2-R-106049
Handle module MGB-H-...
- Intelligent bolt tongue
- Lockout mechanism
- Door handle
- Mounting plate
125577
MGB-L2B-PNA-L-125577
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 2 control elements, 7/8" and M12 plugs
MGB-L2B-PNA-L-125577
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 2 control elements, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2123624
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
UKCA-Konformitätserklärung
Dok. No.
EDC20001506
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ B
Dok. No.
2115174
Versiyon
03/24
Dil
Boyut
3,9 MB
Diğer Belgeler
Approvals and certificates
DGUV
Dok. No.
Versiyon
Dil
Boyut
DGUV
Dok. No.
Versiyon
Dil
Boyut
0,8 MB
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
0,2 MB
ProfiNET
Dok. No.
Versiyon
Dil
Boyut
0,2 MB
TUEV Süd München M6A Zertifikat
Dok. No.
Versiyon
Dil
Boyut
TUEV Süd München M6A Zertifikat
Dok. No.
Versiyon
Dil
Boyut
0,3 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
0,7 MB
Sipariş verileri
Sip. No. | 125576 |
Makale adı | MGB-L2HB-PNA-L-125576 |
Ağırlık | 5,74kg |
Gümrük sınıfı | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |