EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L2B-EIA-R-127676 (Sip. No. 127676)

Locking module MGB-L2...-EI (guard locking by solenoid force) with 2 pushbuttons, emergency stop

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 2 illuminated pushbuttons
  • including adhesive labels
  • Connection via M12 plug
  • Pre-assembled on mounting plates
  • Unicode
MGB-L2B-EIA-R-127676 (Sip. No. 127676)

Açıklama

Dimension drawing
Dimension drawing
Connections
Connections
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Teknik Veriler

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
L1
B0
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
1with adhesive ring2 PDEmergency stop illuminated
21NOIlluminated pushbutton
31NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Ethernet/IP cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
M12 Power, A-coded (X2)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X3)
M12 Power, A-coded (X1)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X4)
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time
Emergency stop / machine stop max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Bolt position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Control of guard locking
Category 4
Performance Level PL e
PFHD 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)

Miscellaneous

Slide-in label
NumberLabelingNote
2without marking
Product version number V1.5
Additional feature incl. lens set, ID no. 120344

Interface

Bus data protocol Ethernet/IP
Safety data protocol CIP Safety
Date interface
Ethernet

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 11,2 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 127676
Makale adı MGB-L2B-EIA-R-127676
Ağırlık 3,75kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.