EUCHNER – More than safety.
EUCHNER – More than safety.

LCA-4TR-S1-14-1060-AP-156611 (Sip. No. 156611)

Light curtain LCA-4TR-S1-14-1060

  • Light curtain slave 1
  • For cascading (series connection)
  • Resolution 14 mm
  • Protective field height 1060 mm
  • Range 6 m
  • With plug connector M12
  • Installation material is included with the product
LCA-4TR-S1-14-1060-AP-156611 (Sip. No. 156611)

Açıklama

Protective function

Finger protection

Cascading (series connection)

Following combinations are possible:

Variant A:

Master-slave 2-slave 1

Variant B:

Master-slave 1

LED function display

Transmitter

Receiver

LED OK

Normal operation

LED ERROR

Error

LED STOP

Stop

LED TEST

Test function

LED START

Start/restart

LED SIGNAL LOW

Weak signal

Connector assignment, transmitter / receiver

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

124 V DCOperating voltage, 24 V DCBN
2LINE_AMASTER-SLAVE communicationWH
30 V DCOperating voltage, 0 V DCBU
4LINE_BMASTER-SLAVE communicationBK
5FEFunctional earth (must be connected to meet the EMC requirements)GY
Wiring diagram
Wiring diagram
Dimension drawing
Dimension drawing
Wiring diagram transmitter
Wiring diagram transmitter
Wiring diagram receiver
Wiring diagram receiver
Light grids and light curtains

Dimensional drawings

Dimensional drawings
1Washer
2Spring washer
3nut
AFastening bracket
BMounting plate

Dimensional drawings

Dimensional drawings
A = Height of the sensor (see technical data)

Connection examples

Connection examples

Connection examples

Connection examples

Teknik Veriler

Approvals

TÜV SÜD München_LCA4_Z10 040393 0045 Rev 00c_UL_us_E492607

Operating and display elements

LED display yes (Self-diagnostics and status)

Electrical connection values

Receiver power consumption 2 W
Transmitter power consumption 1 W
Operating voltage DC 24 V DC -20% ... +20%
Cascadable yes (max. 50 m connecting cable between master and slaves)
Muting possible in combination with external sensors and an evaluation unit
Current consumption 400 mA

Mechanical values and environment

Dimensions 28x30 mm (in cross-section)
Connection type Plug connector M12 (5-pin transmitter/8-pin receiver) (Master-slave1 and master-slave2-slave1 connections are 2x M12, 5-pin)
Resolution 14 mm
Installation orientation any
Height of the protective field 1060 mm
Height of the sensor 1113 mm
maximum length of connecting cables 100 m
Range of the protective field 6000 mm
Degree of protection IP65/IP67
Ambient temperature -20 ... +55 °C

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Safety Integrity Level SIL 3 / SILCL 3

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the protective fieldPL e31.91x10-8420 y


Miscellaneous

ESPE type 4 (according to EN 61496-1)

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 12,0 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 156611
Makale adı LCA-4TR-S1-14-1060-AP-156611
Ağırlık 3,483kg
Gümrük sınıfı 85365019000
ECLASS 27-27-09-10 Light curtain

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.