EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L2-MLI-M-Y0000-BJ-158711 (Sip. No. 158711)

Locking module MGB2-L2-MLI... (module without blanking covers, open-circuit current principle)

  • Guard locking for the protection of persons or processes
  • Locking module MGB2 for connection to a bus module MBM
  • Interlocking with monitored guard locking
  • Category 4/PL e for the evaluation of all safety functions
  • Open version (without blanking covers)
  • Adjustable door hinge
  • Multicode
  • Compatible with all Modular devices
MGB2-L2-MLI-M-Y0000-BJ-158711 (Sip. No. 158711)

Açıklama

Guard locking type

MGB2-L2...

Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid (open-circuit current principle).

Door hinge

On the locking modules, the door stop can be changed from right to left and vice versa at any time with little effort.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

c_UL_us_E155795_3/9TÜV Süd München_Z10 040393 0028 Rev.04EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-02_

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 26,2 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 158711
Makale adı MGB2-L2-MLI-M-Y0000-BJ-158711
Ağırlık 1,19kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.