MGBS-P-L1-AR-U-L-AEE-SH-160873 (Sip. No. 160873)

MGBS-AR, M23, emergency stop, 2 pushbuttons, with escape release, door hinge on left

  • Locking module (order handle module separately)
  • Adjustable door hinge; factory setting: left. The door hinge on left option cannot be ordered separately. Order as spare part 159086.
  • Series connection possible (up to 20 AR devices in series)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • Emergency stop
  • 2 pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • With escape release (order inner door handle separately)
MGBS-P-L1-AR-U-L-AEE-SH-160873 (Sip. No. 160873)

Açıklama

Door hinge

The door hinge can be changed.

Unicode evaluation

Each handle module is highly coded (unicode). The locking module detects only handle modules that have been taught-in. Additional handle modules can be taught-in. Only the last handle module taught-in is detected.

Guard locking type

MGBS-L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Lens set

The color of the pushbuttons can be selected using the color cover set included (5 colors).

Escape release

It is used for manual release of the guard locking without tools in an emergency. The inner door handle permits escape from the danger zone.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPBOperating voltage of guard locking solenoid, 24 V DCVT
2FI1AEnable input, channel 1RD
3FI1BEnable input, channel 2GY
4FO1ASafety output, channel 1RD/BU
5FO1BSafety output, channel 2GN
6UBOperating voltage of AR electronics, controls and indicators 24 V DCBU
7RSTReset inputGY/PK
8ODDoor monitoring outputGN/WH
9OIDiagnostic outputYE/WH
10S1.A1EMERGENCY STOP (channel A)GY/WH
11S1.A2EMERGENCY STOP (channel A)BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13S1.B1EMERGENCY STOP (channel B)PK
14S1.B2EMERGENCY STOP (channel B)BN/GY
15S2Pushbutton 2 (illuminated)BN/YE
16H2LED 2BN/GN
17S3Pushbutton 3 (illuminated)WH
18H3LED 3YE
190 VOperating voltage of AR electronics, controls and indicators 0 V/guard locking solenoid 0 VBN
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MGBS
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings
1Door hinge left/right
2LEDs
3EMERGENCY STOP
4Auxiliary release
5Pushbutton 2, illuminated
6Pushbutton 3, illuminated

Connection examples

Connection examples

Teknik Veriler

Approvals

c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Operating and display elements

ItemColorExtrasVersionNote slide-in labelSwitching elementSlide-in labelNumberDesignation1LED
1Emergency stop2 PD
2Illuminated pushbutton1NO
3Illuminated pushbutton1NO

Electrical connection values

Fuse
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IIMP 400 mA
IUB 40 mA
Test pulse duration max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 140 ms
Degree of contamination (external, according to EN 60947-1) 3
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Monitoring output OD, OI
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay 8 s
Actuating force 10 N
Installation orientation Door hinge DIN left
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch bracket Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-4.1x10-9420 y


B10DMission time
Emergency stop0.13x10620 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature
Escape release actuated by pushing
incl. lens set, ID no. 120344

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 16,3 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 160873
Makale adı MGBS-P-L1-AR-U-L-AEE-SH-160873
Ağırlık 2,2kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.