EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1HB-PN-U-S2-CA-R-161930 (Sip. No. 161930)

Complete set MGB2-L1...-PN (3 pushbuttons, M12 plug connector for enabling switch, closed-circuit current principle, door hinge on right)

  • Guard locking with guard lock monitoring
  • 3 illuminated pushbuttons
  • M12 plug connector for enabling switch
  • Connection via plug connector M12, D-coded, and M12, L-coded
  • Integrated switch
  • Adjustable door hinge; factory setting: right
  • Unicode
MGB2-L1HB-PN-U-S2-CA-R-161930 (Sip. No. 161930)

Açıklama

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

PROFINET interface

Plug connector M12, D-coded (M12 plug, L-coded, and M12 plug, D-coded, according to IEC 61076-2-101)

PROFINET switch

Linear topology network structure due to integrated switch (supports MRP).

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

FCC_2AJ58-02_

Handle modules MGB2-H-BA1A3-R-136691 (Order no. 136691)

Handle modules MGB2-H-BA1A3-R-136691  (Order no. 136691)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Additional feature with automatic lockout mechanism

Bus modules MBM-PN-S2-MLI-3B-161849 (Order no. 161849)

Bus modules MBM-PN-S2-MLI-3B-161849  (Order no. 161849)

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
maximum feed-in current in the connection block
XD1, XD2 max. 16000 mA
Safety class III
Current consumption max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply XD1, XD2
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +15% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +15% (The auxiliary voltage is not required for the MGB system)

Mechanical values and environment

Connection type
M12, L-coded, Power (XD1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
M12, L-coded, Power (XD2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (Only in closed state with correctly mounted caps and the connecting cables or the connected modules)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
ML1C / ML2C
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Insertion cycles 100
ML1D
Connection type Connector (unlocked)
Connection type Male plug
Number of pins 5
Insertion cycles 100

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Locking modules MGB2-L1-MLI-U-YD8A6-CA-R-161924 (Order no. 161924)

Locking modules MGB2-L1-MLI-U-YD8A6-CA-R-161924  (Order no. 161924)

Mechanical values and environment

Installation orientation Door hinge DIN right

Submodules MSM-1-R-DA-M00-A6-137596

Submodules MSM-1-R-DA-M00-A6-137596

Operating and display elements

ItemColorExtrasSwitching elementVersionSlide-in labelNote slide-in labelNumberDesignation1LED
1Connection M12x1 for enabling switch

Electrical connection values

Current consumption max. 16 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (When installed)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic, die-cast zinc, nickel plated

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Evaluating safety signalsPL e-9.06x10-10420 y
Gilt nur für extern angeschlossene Sicherheitsfunktionen wie Zustimmtaster, Sicherheitsschalter usw.


Miscellaneous

Software ID (SW ID) 137596

Modules MGB2-L1-MLI-U-Y0000-BJ-136776

Modules MGB2-L1-MLI-U-Y0000-BJ-136776

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted; assembly.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Connection accessories AC-MC-SB-M-A-157024

Connection accessories AC-MC-SB-M-A-157024

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Submodules MSM-1-P-CA-PPP-D8-161921

Submodules MSM-1-P-CA-PPP-D8-161921

Operating and display elements

ItemColorExtrasSwitching elementSlide-in labelVersionNote slide-in labelNumberDesignation1LED
1Yellowprinted1NOIlluminated pushbutton
2Blueprinted1NOIlluminated pushbutton
3whiteprinted1NOIlluminated pushbutton

Electrical connection values

Current consumption max. 30 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (When installed)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Software ID (SW ID) 9000003

Connection accessories AC-MC-00-0-B-156718

Connection accessories AC-MC-00-0-B-156718

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. fixing screws
incl. seal

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 52,9 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 161930
Makale adı MGB2-L1HB-PN-U-S2-CA-R-161930
Ağırlık 3,89kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.