MSC-CB-AC-FI8FO4S-166057 (Sip. No. 166057)

Base unit MSC-CB-S

  • Freely programmable base unit for use as a standalone device or expandable with various expansion modules
  • 8 single-channel /4 dual-channel inputs
  • up to 4 control inputs
  • 4 single-channel semiconductor outputs (up to PL e, category 4)
  • up to 4 monitoring outputs
  • PC connection for the EUCHNER Safety Designer software
  • Optional memory module for configuration
  • Compact housing with width of only 22.5mm
  • Simple diagnostics via LED displays
MSC-CB-AC-FI8FO4S-166057 (Sip. No. 166057)

Açıklama

Inputs and outputs

  • 8 single-channel/4 dual-channel inputs

  • Up to 4 control inputs for starting/restarting semiconductor outputs or for external device monitoring (EDM)

  • 4 single-channel/2 dual-channel semiconductor outputs (up to PL e, category 4)

  • 4 test outputs for monitoring for short circuits and overload states

  • Up to 4 monitoring outputs programmed via the EUCHNER Safety Designer software
Three settings are available for the safe semiconductor outputs (configuration via the EUCHNER Safety Designer software):
  • 4 single-channel outputs

  • 2 dual-channel outputs

  • 1 dual-channel output and 2 single-channel outputs

MSC system

An MSC system consists of a base unit and max. 14 expansion modules. You can use this base unit to expand your MSC system with max. 128 inputs, 30 dual-channel safe outputs and 48 monitoring outputs. You can use up to 4 expansion modules of the same time in your MSC system.

Accessories

  • Plug-in screw terminals (order no. 121321) must be ordered separately

  • An expansion plug (order no. 121308) is additionally required for use with expansion modules.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MSC: Safe control system MSC

Dimensional drawings

Dimensional drawings
1Page A
2Page B

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0030 Rev.01c_UL_us_E353660_UL_us_E467239

Electrical connection values

Connection cross section 0.5 ... 2.5 mm² (Screw terminal)
Outputs
NumberTypeFunctionFootnote
2Semiconductor outputs, p-switching, short circuit-proofSafety outputs (OSSD)(according to EN 61131-2)
4Semiconductor outputs, p-switchingTest outputs(according to EN 61131-2)
4Semiconductor outputs, p-switchingMonitoring outputs, programmable(according to EN 61131-2)
Output voltage
Safety outputs (OSSD) UB-0.75 ... UB V DC HIGH
Safety outputs (OSSD) 0 ... 2 V DC LOW
Output current
Safety outputs (OSSD) 0 ... 400 mA
Monitoring outputs, programmable max. 100 mA
Operating voltage DC
UB 24 V DC -20% ... +20% PELV (according to EN 60204-1)
Inputs
NumberTypeFunctionFootnote
4Semiconductor inputs, p-switchingFeedback loop monitoring (EDM)(according to EN 61131-2)
8Semiconductor inputs, p-switchingSafety inputs(according to EN 61131-2)
inductive load
Safety outputs (OSSD) max. 2 mH
capacitive load
Safety outputs (OSSD) max. 0.82 μF
Test pulse duration
Test outputs 0.2 ms
Safety outputs (OSSD) 0.1 ms
Test pulse interval 600 ms
Overvoltage category according to IEC EN 60664-1 II
Power dissipation max. 3 W
Degree of contamination according to EN 60664-1 2
Time delay 0.01275 ... 0.06592 s + filter time (Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions or calculated values in the Euchner Safety Designer software))

Mechanical values and environment

Dimensions 108 x 22.5 x 114.5 (Including screw terminals)
Connection type Plug-in screw terminal (Terminals not included)
Storage temperature -20 ... +85 °C
Cable length max. 100 m (with length above 50 m, cross-section>use 1 mm²)
Atmospheric humidity 10 ... 95 % rH
Mounting type TH 35 mounting rail (EN IEC 60715)
Degree of protection IP20
Ambient temperature -10 ... +55 °C
Material
Housing Polyamide
USB port for PC connection
Connection type USB type B - Mini
Cable length max. 3 m

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y (according to ISO 13849-1:2006/IEC 62061:2005)
Category 4 (according to ISO 13849-1:2006/IEC 62061:2005)
Performance Level PL e (according to ISO 13849-1:2006/IEC 62061:2005)
PFHD 1.35E-08 (according to IEC 61508:2010)
SIL CL 3

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 57,0 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 166057
Makale adı MSC-CB-AC-FI8FO4S-166057
Ağırlık 0,23kg
Gümrük sınıfı 85371091
ECLASS 27-24-22-07 SPS-Grundgerät

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.