EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L1HEB-EIA-L-166743 (Sip. No. 166743)

Locking set MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop and key-operated rotary switch

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 3 illuminated pushbuttons
  • OM.R key-operated rotary switch (2-channel)
  • Connection via M12 plug
  • Pre-assembled on mounting plates
  • Integrated switch
  • With escape release
  • Unicode
MGB-L1HEB-EIA-L-166743 (Sip. No. 166743)

Açıklama

Ethernet/IP connection

M12 plug (a-coded) 4-pin according to IEC 61076-2-101

Integrated switch

Point-to-point topology network structure due to integrated switch.

Flexible use as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Escape release

The escape release enables people shut in to open the guard locked door from the danger zone.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Connections
Connections

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Teknik Veriler

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Escape release MGB-E-A2-106051 (Order no. 106051)

Escape release MGB-E-A2-106051  (Order no. 106051)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0
Additional feature with mounting plate

Handle modules MGB-H-AA1A6-L-111839 (Order no. 111839)

Handle modules MGB-H-AA1A6-L-111839  (Order no. 111839)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0
Additional feature with mounting plate and automatic lockout mechanism

Locking modules MGB-L1B-EIA-L-136485 (Order no. 136485)

Locking modules MGB-L1B-EIA-L-136485  (Order no. 136485)

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
B1
L1
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
12 PDEmergency stop
2whiteprinted1NOIlluminated pushbutton
3Red1NOIlluminated pushbutton
4Greenprinted1NOIlluminated pushbutton
91OM.R2NOKey-operated rotary switch

Electrical connection values

Connecting cable
Ethernet Ethernet/IP cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
M12 Power, A-coded (X2)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X4)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X3)
M12 Power, A-coded (X1)
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time
Bolt position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stop max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Key-operated rotary switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Control of guard locking
Category 4
Performance Level PL e
PFHD 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Key-operated rotary switch evaluation
Category 4
Performance Level PL e
PFHD 3.74 x 10-12 (Fixed failure rate without consideration of faults in wearing parts.)
Key-operated rotary switch
B 10
Key-operated rotary switch 0.03 x 10⁶
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)

Miscellaneous

Product version number V1.5

Interface

Bus data protocol Ethernet/IP
Safety data protocol CIP Safety
Date interface
Ethernet

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 11,2 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 166743
Makale adı MGB-L1HEB-EIA-L-166743
Ağırlık 6,98kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.