EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1H-BP-U-S4-OY-R-167025 (Sip. No. 167025)

Complete set MGB2-L1...-BP (M23, closed-circuit current principle, door hinge on right)

  • Guard locking with guard lock monitoring
  • 3 adhesive labels
  • Connection submodule with plug connector M23
  • Adjustable door hinge; factory setting: right
  • Unicode
MGB2-L1H-BP-U-S4-OY-R-167025 (Sip. No. 167025)

Açıklama

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

Flexible adaptation through configuration

  • The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
  • In addition, guard lock monitoring can be switched on or off on devices with guard locking. When guard lock monitoring is switched on, the safe outputs are switched on if the guard is safely locked. When guard lock monitoring is switched off, the safe outputs are switched on if the guard is closed and the bolt tongue is inserted into the MGB2.
  • Release monitoring can be activated when guard lock monitoring is switched on. This signals whether the auxiliary release or escape release was actuated.
  • Factor reset permits resetting to the factory setting.

Adhesive labels

The user can produce custom labeling using the enclosed adhesive labels. (3 pcs., blank)

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

TUEV Süd München_Z10 040393 0029 Rev. 02FCC_2AJ58-03_

Handle modules MGB2-H-BA1A1-R-137617 (Order no. 137617)

Handle modules MGB2-H-BA1A1-R-137617  (Order no. 137617)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Locking modules MGB2-L1-BP-U-XA4S4-OY-R-167027 (Order no. 167027)

Locking modules MGB2-L1-BP-U-XA4S4-OY-R-167027  (Order no. 167027)

Mechanical values and environment

Installation orientation Door hinge DIN right

Submodules MSM-1-N-AA-000-A4-126372

Submodules MSM-1-N-AA-000-A4-126372

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material Fiber glass reinforced plastic

Modules MGB2-L1-BP-U-X0000-BX-162622

Modules MGB2-L1-BP-U-X0000-BX-162622
h3>Electrical connection values
Connection cross section
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16))
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time
between FO1A and FO1B max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Risk time according to EN 60947-5-3 max. 50 ms (In a series connection, the risk time increases by 10 ms for each additional device.)
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Monitoring outputs OD, OT/C, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current max. 50 mA
Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths)
Output current
per safety output FO1A / FO1B 1 ... 150 mA
Turn-on time max. 80 ms
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IUB max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
Power supply IMP, IMM
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IIMP max. 375 mA
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms

Mechanical values and environment

Ready delay 5 s
Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic; die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.95x10-9420 y
Monitoring of the guard positionPL e32.95x10-9420 y
Monitoring of guard lockingPL e32.95x10-9420 y


Connection accessories AC-MC-00-0-B-156718

Connection accessories AC-MC-00-0-B-156718

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. fixing screws
incl. seal

Submodules MSM-C-K-BA-SH0-S4-167011

Submodules MSM-C-K-BA-SH0-S4-167011

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature -25 ... +55 °C
Material Glass fiber reinforced plastic; CuZn, nickel plated
Connection 1
Connection type Socket connectors, coded
Insertion cycles 25
Connection 2
Connection type Plug connector M23
Connection type Male plug
Number of pins 19
Plug lock Screw connection
Insertion cycles 100

Miscellaneous

Slide-in label
NumberLabelingNote
3without marking
Additional feature
Incl. label holder, ID no. 156733
incl. pre-assembled socket connectors

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 21,8 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 167025
Makale adı MGB2-L1H-BP-U-S4-OY-R-167025
Ağırlık 2,58kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.