EUCHNER – More than safety.
EUCHNER – More than safety.
 

MGB2-L2HE-MLI-U-CC-R-174333 (Sip. No. 174333)

Locking set MGB2-L2... (2 pushbuttons illuminated with symbol, EMERGENCY STOP, key-operated rotary switch, CKS2 key adapter, insert plate, open-circuit current principle, door hinge right)

  • Guard locking with guard lock monitoring
  • Illuminated emergency stop according to ISO 13850
  • Selector switch 1 x 90° Form V, illuminated
  • 2 illuminated pushbuttons with symbol
  • CKS2 key adapter with integrated evaluation electronics
  • Key-operated rotary switch 1 x 90°, form V
  • Freely controllable LEDs (red, green, yellow)
  • Additional RGB LED for simple diagnostics
  • Cut-out for slide-in label
  • Incl. color slide-in labels
  • incl. 2 keys (OM.R-165433)
  • Adjustable door hinge; factory setting: right
  • With escape release
  • Unicode
  • For connection to any bus module MBM
  • Remote or direct mounting of bus module MBM
MGB2-L2HE-MLI-U-CC-R-174333 (Sip. No. 174333)

Açıklama

Guard locking type

MGB2-L2...

Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. (open-circuit current principle)

Category according to EN 13849-1

The CKS2 system can be integrated into installations with the highest safety requirements, such as category 4 / PL e according to EN ISO 13849-1.

Important! CKS2 keys must be ordered separately!

Remote mounting

If space is limited, the bus module can be remotely mounted on the locking set.

Flexible connection to any bus module MBM

The locking set can be connected to any bus module MBM, making it the ideal choice for supplementing or expanding existing systems.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-02_

Escape release MGB-E-A-100465 (Order no. 100465)

Escape release MGB-E-A-100465  (Order no. 100465)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0

Handle modules MGB2-H-BA1A8-R-157021 (Order no. 157021)

Handle modules MGB2-H-BA1A8-R-157021  (Order no. 157021)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Additional feature
with automatic lockout mechanism
Can be locked using escape release

Locking modules MGB2-L2-MLI-U-YP6P8-CC-R-174373 (Order no. 174373)

Locking modules MGB2-L2-MLI-U-YP6P8-CC-R-174373  (Order no. 174373)

Mechanical values and environment

Installation orientation Door hinge DIN right

Connection accessories AC-MC-SB-M-A-157024

Connection accessories AC-MC-SB-M-A-157024

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Connection accessories AC-MC-SB-F-A-157028

Connection accessories AC-MC-SB-F-A-157028

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Female plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Female plug
Type specification M12 EN 61076-2-101
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Modules MGB2-L2-MLI-U-Y0000-BJ-156392

Modules MGB2-L2-MLI-U-Y0000-BJ-156392

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
when used as a door hinge and 2 joules of impact energy 0.1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.2 x 10⁶
Total 1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted; assembly.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Submodules MSM-1-P-CA-BPP-P6-174318

Submodules MSM-1-P-CA-BPP-P6-174318

Operating and display elements

ItemColorExtrasSlide-in labelVersionSwitching elementNote slide-in labelNumberDesignation1LED
1Illuminated emergency stop2 PD
2BlueprintedIlluminated pushbutton1NO
3WhiteprintedIlluminated pushbutton1NO

Electrical connection values

Current consumption max. 32 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC
Illuminated emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (When installed)
Ambient temperature
with UB = 24V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Software ID (SW ID) 9000001

Submodules MSM-1-R-CKS2-FLX-W0Q0FS-P8-174324

Submodules MSM-1-R-CKS2-FLX-W0Q0FS-P8-174324

Operating and display elements

ItemColorExtrasVersionSlide-in labelNote slide-in labelSwitching elementNumberDesignation1LED
1OM.RKey-operated rotary switch2NO
212.5x27 mmPosition for slide-in label
3CKS2 key system

Electrical connection values

Current consumption max. 50 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (When installed)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Safe key detectionPL e33.37x10-9420 y


B10DMission time
Safe key-operated rotary switch0.06x10620 y


Miscellaneous

Slide-in label
NumberLabelingNote
1without marking
Software ID (SW ID) 9000063

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 34,4 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 174333
Makale adı MGB2-L2HE-MLI-U-CC-R-174333
Ağırlık 3,54kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.