AnasayfaProductsSafety engineering for connection to IO-LinkBP/BR safety switch without guard locking
BP/BR safety switch without guard locking
Benefits for you
- Communicating safety switch
- Industry 4.0 ready
- Safety category 4 and PL e according to EN ISO 13849-1.
Industry 4.0 ready
Switches from system families BP and BR can communicate in combination with an EUCHNER IO-Link Gateway, and send process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.
Diagnostic information
The safety switches in this group can forward comprehensive diagnostic information to the control system. The devices supply process-relevant parameters in real time. They even provide information on preventive maintenance.The sensors measure relevant parameters in the surroundings to indicate problems before a machine failure can occur. In combination with the IO-Link Gateways GWY-CB and ESM-CB, this information is polled from every switch and provided to the control system via IO-Link.
Ürünler (7)
Sonuç bulunamadı

160076
CES-I-BP-M-C07-SB-160076
Non-contact safety switches CES-I-BP-.-C07, M12
CES-I-BP-M-C07-SB-160076
Non-contact safety switches CES-I-BP-.-C07, M12
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Multicode
- M12 plug connector, 5-pin
- With door monitoring output OD
- Diagnostics via IO-Link with safety module ESM-CB
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces

162813
CES-I-BP-M-C07-SI-162813
Non-contact safety switches CES-I-BP-.-C07, M12
CES-I-BP-M-C07-SI-162813
Non-contact safety switches CES-I-BP-.-C07, M12
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Multicode
- M12 plug connector, 5-pin (pin 5 not used)
- Direct connection to IP67 field modules
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces

160080
CES-I-BP-U-C07-SB-160080
Non-contact safety switches CES-I-BP-.-C07, M12
CES-I-BP-U-C07-SB-160080
Non-contact safety switches CES-I-BP-.-C07, M12
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Unicode
- M12 plug connector, 5-pin
- With door monitoring output OD
- Diagnostics via IO-Link with safety module ESM-CB
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces

162815
CES-I-BP-U-C07-SI-162815
Non-contact safety switches CES-I-BP-.-C07, M12
CES-I-BP-U-C07-SI-162815
Non-contact safety switches CES-I-BP-.-C07, M12
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Unicode
- M12 plug connector, 5-pin (pin 5 not used)
- Direct connection to IP67 field modules
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces

165914
CES-I-BR-CC-FLX-C07-SA-165914
Non-contact safety switches CES-I-BR-CC-FLX-C07, with FlexFunction, suitable for actuators with same coding
CES-I-BR-CC-FLX-C07-SA-165914
Non-contact safety switches CES-I-BR-CC-FLX-C07, with FlexFunction, suitable for actuators with same coding
- Safety switch with integrated evaluation electronics
- Suitable for actuator with same coding
- Several devices can be connected in series, max. 20
- Switch chains up to 200 m long
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Diagnostic information via BR IO-Link Gateway
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Plug connector M12, 8-pin (aligned)
- The safety switch can be used only in conjunction with actuators designated for this purpose.

156233
CES-I-BR-M-C07-SA-156233
Non-contact safety switches CES-I-BR-.-C07, M12
CES-I-BR-M-C07-SA-156233
Non-contact safety switches CES-I-BR-.-C07, M12
- Safety switch with integrated evaluation electronics
- Several devices can be connected in series, max. 20
- Multicode
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Monitoring output OD
- Diagnostic information via BR/IO-Link Gateway GWY-CB or ESM-CB
- Three active faces
- Plug connector M12, 8-pin (aligned)
- Switch chains up to 200 m long

157920
CES-I-BR-U-C07-SA-157920
Non-contact safety switches CES-I-BR-.-C07, M12
CES-I-BR-U-C07-SA-157920
Non-contact safety switches CES-I-BR-.-C07, M12
- Safety switch with integrated evaluation electronics
- Several devices can be connected in series, max. 20
- Unicode
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Monitoring output OD
- Diagnostic information via BR/IO-Link Gateway GWY-CB or ESM-CB
- Three active faces
- Plug connector M12, 8-pin (aligned)
- Switch chains up to 200 m long