TX safety switch, cable entry M20 x 1.5
- 3 x cable entry M20 x 1.5
- Contacts for the door position
- Auxiliary release
- LED indicator
- Open-circuit current principle

Açıklama
LED indicator
The switch has two freely assignable LED indicators (red and green).
Guard locking principle
Operating current (power to lock): In the case of a safety guard with guard locking according to the open-circuit current principle, the safety guard is locked until the power supply to the guard locking solenoid is break-before-make. The guard is unlocked by spring force. This is also referred to as electrical guard locking.
Switching element
ETX D | Slow-action switching contact |
Contacts for guard locking: 2 positively driven, positively driven contacts | |
Contacts for door monitoring: 2 positively driven, positively driven contacts |
Auxiliary release
The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).
Required accessories
Actuator is not included in the scope of delivery.
Functional drawings

Dimensional drawings

1 | Auxiliary release |
2 | LED indicator |
3 | Locking screw |
s | Insertion depth |
Connection examples

Teknik Veriler
Approvals




Operating and display elements
LED display | Operating voltage corresponds to the solenoid voltage (2 LEDs; green, red) |
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position positively driven contacts | 2 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +80 °C |
Material | |
Housing | Die-cast alloy cathodically dipped |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler

Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità

Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità


Mode d’emploi Interrupteur de sécurité TX…
Betriebsanleitung Sicherheitsschalter TX…
Istruzioni di impiego Finecorsa di sicurezza TX…


Diğer Belgeler










CAD Verileri
Sipariş verileri
Sip. No. | 095026 |
Makale adı | TX2D-A024MC2081 |
Ağırlık | 0,869kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |