Safety switch TX, release under load
- Auxiliary release on the front
- Release under load possible
- With door monitoring contact
![TX3B-A024M (Sip. No. 082952)](https://assets2.euchner.de/files/52/46/ast_735246_xl.png)
Açıklama
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
LED function display
The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.
Guard locking type
TX3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. Release under load possible. |
Switching element
ETX B | Slow-action switching contact 2 NC |
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
![Switching function](https://assets2.euchner.de/files/33/09/ast_653309_m.png)
![Dimension drawing](https://assets2.euchner.de/files/45/60/ast_634560_m.png)
![Wiring diagram ETX BAC/DC 24 V](https://assets2.euchner.de/files/54/21/ast_655421_m.png)
![](https://assets2.euchner.de/files/85/29/738529_m.png)
Functional drawings
![Functional drawings](https://assets2.euchner.de/files/33/09/ast_653309.png)
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/45/60/ast_634560.png)
1 | Auxiliary release |
2 | LED indicator |
3 | Locking screw |
s | Insertion depth |
Connection examples
![Connection examples](https://assets2.euchner.de/files/54/21/ast_655421.png)
Teknik Veriler
Approvals
![EAC_RU C-DE.MO05.B.00971/20](https://assets2.euchner.de/files/06/97/ast_630697_m.png)
![DNV-GL_TAA0000172 Rev. 1](https://assets2.euchner.de/files/07/53/ast_630753_m.png)
![CCC2024010305643586_SafetySwitch T_ST](https://assets2.euchner.de/files/07/52/ast_630752_m.png)
![c_UL_us_E155795_2/1](https://assets2.euchner.de/files/82/74/ast_628274_m.png)
Operating and display elements
LED display | Operating voltage corresponds to the solenoid voltage (2 LEDs; green, red) |
Electrical connection values
Power consumption | 8 W (48 W at the instant switched on) |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 230 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
Control voltage | |
Us AC/DC | 24 V |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position NC contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 50 N (Unlocking under load) |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +80 °C |
Material | |
Housing | Die-cast alloy cathodically dipped |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Guard locking principle | Closed-circuit current principle (Unlocking under load) |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
![Dok. No. EDC2539628](https://assets2.euchner.de/files/33/55/ast_2263355_thumb.jpg)
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
![Dok. No. EDC2539628](https://assets2.euchner.de/files/33/57/ast_2263357_thumb.jpg)
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
![Dok. No. EDC20001551](https://assets2.euchner.de/files/97/28/ast_2329728_thumb.jpg)
![Dok. No. 2079777](https://assets2.euchner.de/files/35/21/ast_3143521_thumb.jpg)
Mode d’emploi Interrupteur de sécurité TX…
Betriebsanleitung Sicherheitsschalter TX…
Istruzioni di impiego Finecorsa di sicurezza TX…
![Dok. No. 2079777](https://assets2.euchner.de/files/35/20/ast_3143520_thumb.jpg)
![Dok. No. 2079777](https://assets2.euchner.de/files/46/75/ast_3034675_thumb.jpg)
Diğer Belgeler
![Dok. No. 20001753](https://assets2.euchner.de/files/55/29/ast_3295529_thumb.jpg)
![Dok. No.](https://assets2.euchner.de/files/68/20/ast_2576820_thumb.jpg)
![Dok. No.](https://assets2.euchner.de/files/33/82/ast_743382_thumb.jpg)
![Dok. No. 100369](https://assets2.euchner.de/files/82/34/ast_438234_thumb.jpg)
![Dok. No. 100676](https://assets2.euchner.de/files/82/35/ast_438235_thumb.jpg)
![Dok. No. 104856](https://assets2.euchner.de/files/82/38/ast_438238_thumb.jpg)
![Dok. No. 100319](https://assets2.euchner.de/files/82/36/ast_438236_thumb.jpg)
![Dok. No. 102453](https://assets2.euchner.de/files/82/33/ast_438233_thumb.jpg)
![Dok. No. 121650](https://assets2.euchner.de/files/82/37/ast_438237_thumb.jpg)
CAD Verileri
Sipariş verileri
Sip. No. | 082952 |
Makale adı | TX3B-A024M |
Ağırlık | 0,868kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |