EUCHNER – More than safety.
EUCHNER – More than safety.

TP3-4141A024RC18EXT1 (Sip. No. 103339)

Safety switch TP, plug connector RC18, pushbutton and cover for indicators, with door monitoring contact

  • Auxiliary release on the front
  • Pushbutton and cover for indicators
  • With door monitoring contact
  • Increased horizontal overtravel
  • Plug connector
TP3-4141A024RC18EXT1 (Sip. No. 103339)

Açıklama

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel for horizontal approach direction

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Cover for indicators

A cover for indicators (1 LED, green) is available for the following voltage ranges:

  • DC 24 V +10%,-15%

Pushbuttons

  • Black push button

Guard locking type

TP3

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

4141

Slow-action switching contact 2 NC + 2 NC (door monitoring contact)

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram 4141 EXT1
Wiring diagram 4141 EXT1
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3Cover for indicators, green
4Black push button

Connection examples

Connection examples
Door monitoring
Solenoid monitoring

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010305643586_SafetySwitch T_STDGUV_ET 20002_ET 20003

Electrical connection values

Power consumption 8 W
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 1.5 kV
Utilization category
AC-15 4 A 50 V
DC-13 4 A 24 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed max. 20 m/min
Connection type
1 x Built-in connector RC18 (18-pin)
Number of door position positively driven contacts 2
Number of guard lock monitoring positively driven contacts 2
Extraction force 20 N
Actuation frequency max. 1200 1/h
Actuating force 10 N
Installation orientation any
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP54
Ambient temperature -20 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

Additional feature
1 x cover for indicators Green (24 V DC)
1 x pushbutton black (24 V (breaking capacity max. 250 mW))

In combination with actuator ACTUATOR-P-GNT

Horizontal overtravel 7 mm

In combination with actuator ACTUATOR-P-GT

Horizontal overtravel 2 mm
Vertical overtravel 1.5 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 7,4 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 103339
Makale adı TP3-4141A024RC18EXT1
Ağırlık 0,552kg
Gümrük sınıfı 85371098
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.