Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, selector switch and emergency stop
- Guard locking with guard lock monitoring
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 1 pushbutton (illuminated, wh)
- With lens set, 6 pcs.
- Selector switch (form V, 2x40°)
- With cable entry
- Unicode
![MGB-L1-ARA-AN6A1-M-R-160587 (Sip. No. 160587)](https://assets2.euchner.de/files/97/37/ast_669737_xl.png)
Açıklama
Guard locking type
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
Door hinge
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics; there is a fault |
Emergency stop device
S1 | 2 positively driven contacts, emergency stop with turn-to-reset, not illuminated |
Pushbuttons
S2 | 1 NO contact, illuminated |
Selector switch
S3 | Spring return selector switch with 3 positions (form V, 2 x 40°). |
![Dimension drawing](https://assets2.euchner.de/files/05/26/ast_640526_m.png)
![Wiring diagram](https://assets2.euchner.de/files/15/44/ast_661544_m.png)
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/05/26/ast_640526.png)
Connection examples
![Connection examples](https://assets2.euchner.de/files/15/44/ast_661544.png)
Teknik Veriler
Approvals
![c_UL_us_E155795_3/9](https://assets2.euchner.de/files/82/74/ast_628274_m.png)
![EAC_RU C-DE.HX37.B.14157/20](https://assets2.euchner.de/files/06/97/ast_630697_m.png)
![FCC_2AJ58-09_](https://assets2.euchner.de/files/08/42/ast_630842_m.png)
Operating and display elements
Occupancy diagram | L1 |
Item | Color | Extras | Note slide-in label | Version | Slide-in label | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Emergency stop | 2 PD | |||||||
2 | Illuminated pushbutton | 1NO | |||||||
3 | Selector switch | 2NO |
Electrical connection values
Connection cross section | |
(rigid/flexible) | 0.13 ... 1.5 mm² ((AWG 24 ... AWG 16)) |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 350 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 1 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUA | max. 375 mA ((with energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V)) |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUB | max. 80 mA ((no load on outputs)) |
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Degree of protection | IP65 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Control of guard locking | PL e | - | 2.8x10-9 | 4 | 20 y |
Monitoring of the guard position | PL e | - | 3.7x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | - | 3.7x10-9 | 4 | 20 y |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Miscellaneous
Slide-in label | |||||||
| |||||||
Product version number | V4.0.0 | ||||||
Additional feature | incl. lens set, ID no. 120344 |
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
![Dok. No. 2119167](https://assets2.euchner.de/files/32/74/ast_3053274_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/81/ast_3053281_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/70/ast_3053270_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/29/75/ast_3042975_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/77/ast_3053277_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/72/ast_3053272_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/83/ast_3053283_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/79/ast_3053279_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/69/ast_3053269_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/80/ast_3053280_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/71/ast_3053271_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/82/ast_3053282_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/75/ast_3053275_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/76/ast_3053276_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/78/ast_3053278_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/73/ast_3053273_thumb.jpg)
![Dok. No. 2119167](https://assets2.euchner.de/files/32/68/ast_3053268_thumb.jpg)
Diğer Belgeler
![Dok. No.](https://assets2.euchner.de/files/36/73/ast_743673_thumb.jpg)
![Dok. No.](https://assets2.euchner.de/files/36/72/ast_743672_thumb.jpg)
![Dok. No.](https://assets2.euchner.de/files/11/09/ast_2001109_thumb.jpg)
![Dok. No. ECO2123125](https://assets2.euchner.de/files/34/55/ast_3223455_thumb.jpg)
Sipariş verileri
Sip. No. | 160587 |
Makale adı | MGB-L1-ARA-AN6A1-M-R-160587 |
Ağırlık | 0,kg |
Gümrük sınıfı | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |