Locking set MGB-L1...-EI (Guard locking by spring force) with 4 pushbuttons, EMERGENCY STOP
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 4 illuminated pushbuttons
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Unicode

Teknik Veriler
Approvals


Handle modules MGB-H-AA1A6-L-111839 (Order no. 111839)

Mechanical values and environment
Installation orientation | Door hinge DIN left |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate and automatic lockout mechanism |
Locking modules MGB-L1B-EIA-L-136480 (Order no. 136480)

Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B1 | |
L1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | with adhesive ring | 2 PD | Emergency stop illuminated | ||||||
90 | 1NO | Illuminated pushbutton | |||||||
92 | 1NO | Illuminated pushbutton | |||||||
93 | 1NO | Illuminated pushbutton | |||||||
95 | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Ethernet/IP cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) |
7/8" Power (X2) | |
7/8" Power (X1) | |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Monitoring of guard locking and the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Miscellaneous
Slide-in label | |||||||
| |||||||
Product version number | V1.5 | ||||||
Additional feature | incl. lens set, ID no. 120344 |
Interface
Bus data protocol | Ethernet/IP |
Safety data protocol | CIP Safety |
Date interface | |
Ethernet |
Bileşenler

111839
MGB-H-AA1A6-L-111839
Handle module MGB-H... with automatically extending lockout mechanism
MGB-H-AA1A6-L-111839
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate

136480
MGB-L1B-EIA-L-136480
Locking module MGB-L1...-EI (Guard locking by spring force) with 4 pushbuttons, EMERGENCY STOP, 7/8" and M12 plug
MGB-L1B-EIA-L-136480
Locking module MGB-L1...-EI (Guard locking by spring force) with 4 pushbuttons, EMERGENCY STOP, 7/8" and M12 plug
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 4 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Unicode
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

EU-Konformitätserklärung
Dok. No.
EDC2123624
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut

UKCA-Konformitätserklärung
Dok. No.
EDC20001506
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Dok. No.
Versiyon
Dil
Boyut

Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Dok. No.
2126330
Versiyon
09/21
Dil
Boyut
2,9 MB

Manual de instrucciones Sistemas de seguridad MGB-L..B-EI-… (Ethernet/IP) y con estructura de datos de tipo A V1.5.0 o superior
Dok. No.
2126330
Versiyon
09/21
Dil
Boyut
3,0 MB

Betriebsanleitung Sicherheitssysteme MGB-L..B-EI-… (Ethernet/IP) und mit Datenstruktur Typ A ab V1.5.0
Dok. No.
2126330
Versiyon
09/21
Dil
Boyut
2,9 MB

사용 설명서 안전 시스템 MGB-L..B-EI-…(이더넷/IP) 데이터 구조 타입 A 포함 V1.5.0부터
Dok. No.
2126330
Versiyon
09/21
Dil
Boyut
3,3 MB

Instrucțiuni de utilizare Sisteme de siguranță MGB-L..B-EI-… (Ethernet/IP) și cu structură de date tip A începând de la versiunea V1.5.0
Dok. No.
2126330
Versiyon
09/21
Dil
Boyut
3,1 MB
Diğer Belgeler
Approvals and certificates
c UL us
Dok. No.
Versiyon
Dil
Boyut

c UL us
Dok. No.
Versiyon
Dil
Boyut
0,7 MB
Sipariş verileri
Sip. No. | 159095 |
Makale adı | MGB-L1HB-EIA-L-159095 |
Ağırlık | 5,92kg |
Gümrük sınıfı | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |