EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L1HECB-PNA-L-124821 (Sip. No. 124821)

Locking set with control and bus module MGB-...-PN with 11 controls and indicators, 7/8" and M12 plugs, RC12

  • Control panel
  • Emergency stop according to ISO 13850, illuminated
  • 9 illuminated pushbuttons
  • Operating mode selector
  • Connection via 7/8" and M12 plugs
  • including terminal plug for stack light (M12, 5-pin)
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • With escape release
  • Unicode
MGB-L1HECB-PNA-L-124821 (Sip. No. 124821)

Açıklama

Profinet connection

7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Escape release

The escape release enables people accidentally shut in to open the guard locked door from the danger zone.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9ProfiNET_Z10436_Version2024EAC_RU C-DE.HX37.B.14157/20DGUV_LB.520.38/09260/I_

Escape release MGB-E-A2-106051 (Order no. 106051)

Escape release MGB-E-A2-106051  (Order no. 106051)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0
Additional feature with mounting plate

Handle modules MGB-H-AA1A6-L-111839 (Order no. 111839)

Handle modules MGB-H-AA1A6-L-111839  (Order no. 111839)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0
Additional feature with mounting plate and automatic lockout mechanism

Locking modules MGB-L1CB-PNA-L-124820 (Order no. 124820)

Locking modules MGB-L1CB-PNA-L-124820  (Order no. 124820)

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
L0
B2
C1
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
10white1NOIlluminated pushbutton
11white1NOIlluminated pushbutton
12Greenprinted1NOIlluminated pushbutton
132 PDEmergency stop illuminated
14white1NOIlluminated pushbutton
15Yellowprinted1NOIlluminated pushbutton
16white1NOIlluminated pushbutton
17white1NOIlluminated pushbutton
90whiteprinted1NOIlluminated pushbutton
91Code 2 of 3O ; IOperating mode selector
92Blueprinted1NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
for enabling switch Plug connector RC12 (X14)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
for Stacklight Plug connector M12 (X6)
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time
Bolt position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Miscellaneous

Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 6,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 124821
Makale adı MGB-L1HECB-PNA-L-124821
Ağırlık 7,959kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.