EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-I-BR-U-X0000-JX-157957 (Sip. No. 157957)

Interlocking module MGB2-I-BR... (module without blanking covers)

  • Interlocking (without guard locking)
  • Interlocking module MGB2 for direct connection to a control system
  • Category 4/PL e for the evaluation of all safety functions
  • Open version (without blanking covers)
  • Adjustable door hinge
  • Unicode
  • Compatible with BR technology
MGB2-I-BR-U-X0000-JX-157957 (Sip. No. 157957)

Açıklama

Guard locking type

MGB2-I...

The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position.

Flexible adaptation through configuration

  • The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
  • Factor reset permits resetting to the factory setting.

Door hinge

On the locking/interlocking modules, the door hinge can be changed from right to left and vice versa at any time with little effort.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

c_UL_us_E155795_3/9TUEV Süd München_Z10 040393 0029 Rev. 02EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-03_

Electrical connection values

Connection cross section
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16))
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time
between FO1A and FO1B max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Risk time according to EN 60947-5-3 max. 50 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Monitoring outputs OD, OT/C, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current max. 50 mA
Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths)
Output current
per safety output FO1A / FO1B 1 ... 150 mA
Turn-on time max. 80 ms
Test pulse duration max. 0.3 ms
Test pulse interval min. 100 ms
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Current consumption
IUB max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)

Mechanical values and environment

Ready delay 5 s
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted; assembly.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic; die-cast zinc, nickel plated

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e32.95x10-9420 y


Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 13,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 157957
Makale adı MGB2-I-BR-U-X0000-JX-157957
Ağırlık 0,985kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.