Interlocking module MGB2-I-BR... (2 pushbuttons, emergency stop, door hinge on right)
- Interlocking (without guard locking)
- Emergency stop according to ISO 13850
- 2 illuminated white pushbuttons with symbol
- 3 adhesive labels
- Cable entry M20 x 1.5 (order cable gland separately)
- Adjustable door hinge; factory setting: right
- Unicode
- Compatible with BR technology
Açıklama
Guard locking type
MGB2-I... | The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position. |
Flexible adaptation through configuration
- The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
- Factor reset permits resetting to the factory setting.
Door hinge
On the locking/interlocking modules, the door hinge can be changed from right to left and vice versa at any time with little effort.
Lens set
The color of the pushbuttons can be selected using the lens set 120344 included (5 colors).
Adhesive labels
The user can produce custom labeling using the enclosed adhesive labels. (3 pcs., blank)
Dimensional drawings
Dimensional drawings
Teknik Veriler
Approvals
Mechanical values and environment
Installation orientation | Door hinge DIN right |
Submodules MSM-1-K-CA-CPP-B2-137732 (Order no. 137732)
Operating and display elements
Item | Color | Extras | Switching element | Version | Note slide-in label | Slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | 2 PD + 1 NO | Emergency stop with monitoring contact | |||||||
2 | 1NO | Illuminated pushbutton | |||||||
3 | 1NO | Illuminated pushbutton |
Electrical connection values
Current consumption | max. 24 mA |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | 24 V |
Switching current | 5 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Mechanical values and environment
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.) |
Ambient temperature | |
with UB = 24 V DC | -25 ... +55 °C |
Material | Fiber glass reinforced plastic |
Miscellaneous
Additional feature | incl. lens set, ID no. 120344 |
Interlocking modules MGB2-I-BR-U-X0000-JJ-158170 (Order no. 158170)
Electrical connection values
Connection cross section | |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
(rigid/flexible) | 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16)) |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Risk time according to EN 60947-5-3 | max. 50 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs OD, OT/C, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths) |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Turn-on time | max. 80 ms |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Current consumption | |
IUB | max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs) |
Mechanical values and environment
Ready delay | 5 s |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.) |
Ambient temperature | |
with UB = 24 V DC | -25 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated |
Submodules MSM-C-K-BA-SBS-S0-160847 (Order no. 160847)
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.) |
Ambient temperature | -25 ... +55 °C |
Material | Fiber glass reinforced plastic |
Miscellaneous
Slide-in label | |||||||
| |||||||
Additional feature | |||||||
incl. socket connector set, ID no. 136572 | |||||||
Incl. label holder, ID no. 156733 |
AC-MC-00-0-B-156718 (Order no. 156718)
Electrical connection values
Degree of contamination according to EN 60664-1 | 3 |
Mechanical values and environment
Ambient temperature | -30 ... +55 °C |
Material | Fiber glass reinforced plastic |
Connection 1 | |
Connection type | 2x M4 screws |
Degree of protection | IP65 (Only in the screwed tight state with the specified base units.) |
Miscellaneous
Color | black |
Additional feature | |
incl. fixing screws | |
incl. seal |
Bileşenler
MSM-1-K-CA-CPP-B2-137732
Submodule MSM-1-K... (emergency stop, 2 illuminated pushbutton)
- Function expansion
- Connection type: K
- 1 emergency stop according to ISO 13850
- 2 illuminated pushbuttons
- incl. lens set
MGB2-I-BR-U-X0000-JJ-158170
Interlocking module MGB2-I-BR... (module without blanking covers)
- Interlocking (without guard locking)
- Interlocking module MGB2 for direct connection to a control system
- Category 4/PL e for the evaluation of all safety functions
- Open version (without blanking covers)
- Connection for signal light/enabling switch
- Adjustable door hinge
- Unicode
- Compatible with BR technology
MSM-C-K-BA-SBS-S0-160847
Connection submodule MSM-C... (cable entry M20 x 1.5, incl. 3 adhesive labels)
- Connection submodule for MGB2 Classic
- Cable entry M20 x 1.5 (order cable gland separately)
AC-MC-00-0-B-156718
Cover for unused module connections
- Cover for unused connections
- incl. fixing screws
- incl. seal
Aksesuar
MGB2-H-BA1A3-R-136691
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Adjustable door hinge; factory setting: right
MGB2-H-BA1A6-R-157369
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
- Adjustable door hinge; factory setting: right
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Diğer Belgeler
Sipariş verileri
Sip. No. | 158398 |
Makale adı | MGB2-I-BR-U-XB2S0-LB-R-158398 |
Ağırlık | 0,kg |
Gümrük sınıfı | 85371098 |
ECLASS | 27-27-24-03 Safety-related transponder switch |