EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1HB-PN-U-S4-MA-R-161652 (Sip. No. 161652)

Complete set MGB2-L1...-PN (2 pushbuttons, emergency stop, closed-circuit current principle, door hinge on right)

  • Guard locking with guard lock monitoring
  • Illuminated emergency stop according to ISO 13850
  • 2 illuminated white pushbuttons with symbol
  • 3 slide-in labels
  • Connection via plug connector M12, D-coded
  • Integrated switch
  • Adjustable door hinge; factory setting: right
  • Unicode
MGB2-L1HB-PN-U-S4-MA-R-161652 (Sip. No. 161652)

Açıklama

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

PROFINET interface

Plug connector M12 D-coded (7/8" plug and M12 plug, D-coded) according to IEC 61076-2-101

PROFINET switch

Linear topology network structure due to integrated switch (supports MRP).

Slide-in labels

The user can produce custom labeling using the enclosed slide-in labels. (3 pcs., blank)

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

FCC_2AJ58-02_

Handle modules MGB2-H-BA1A3-R-136691 (Order no. 136691)

Handle modules MGB2-H-BA1A3-R-136691  (Order no. 136691)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Additional feature with automatic lockout mechanism

Locking modules MGB2-L1-MLI-U-YB1D5-MA-R-161648 (Order no. 161648)

Locking modules MGB2-L1-MLI-U-YB1D5-MA-R-161648  (Order no. 161648)

Mechanical values and environment

Installation orientation Door hinge DIN right

Bus modules MBM-PN-S4-MLI-3B-156312 (Order no. 156312)

Bus modules MBM-PN-S4-MLI-3B-156312  (Order no. 156312)

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
maximum feed-in current in the connection block
XD1, XD2 max. 6000 mA
Safety class III
Current consumption max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply XD1, XD2
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +15% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +15% (The auxiliary voltage is not required for the MGB system)

Mechanical values and environment

Connection type
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
7/8" Power (XD1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
7/8" Power (XD2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (Only in closed state with correctly mounted caps and the connecting cables or the connected modules)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
ML1C / ML2C
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Insertion cycles 100
ML1D
Connection type Connector (unlocked)
Connection type Male plug
Number of pins 5
Insertion cycles 100

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Modules MGB2-L1-MLI-U-Y0000-BJ-136776

Modules MGB2-L1-MLI-U-Y0000-BJ-136776
h3>Electrical connection values
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Submodules MSM-1-N-AA-QQQ-B1-137610

Submodules MSM-1-N-AA-QQQ-B1-137610

Operating and display elements

ItemColorExtrasVersionSwitching elementSlide-in labelNote slide-in labelNumberDesignation1LED
1Position for slide-in label
2Position for slide-in label
3Position for slide-in label

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Slide-in label
NumberLabelingNote
3without marking
Additional feature Incl. label holder, ID no. 156732

Connection accessories AC-MC-SB-M-A-157024

Connection accessories AC-MC-SB-M-A-157024

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Submodules MSM-1-P-CA-BPP-D5-161589

Submodules MSM-1-P-CA-BPP-D5-161589

Operating and display elements

ItemColorExtrasSwitching elementVersionNote slide-in labelSlide-in labelNumberDesignation1LED
12 PDIlluminated emergency stop
2whiteprinted1NOIlluminated pushbutton
3whiteprinted1NOIlluminated pushbutton

Electrical connection values

Current consumption max. 32 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC
Illuminated emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Software ID (SW ID) 9000001

Connection accessories AC-MC-00-0-B-156718

Connection accessories AC-MC-00-0-B-156718

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. fixing screws
incl. seal

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 52,9 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 161652
Makale adı MGB2-L1HB-PN-U-S4-MA-R-161652
Ağırlık 3,87kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.