EUCHNER – More than safety.
EUCHNER – More than safety.

GSBF03D16-1508-M (Sip. No. 096066)

Series GSBF... 16 mm, mechanical

  • Plunger spacing 16 mm
  • Upright housing
  • Degree of protection IP67 according to IEC 60529
GSBF03D16-1508-M (Sip. No. 096066)

Açıklama

Switching elements

ES 502 E

Snap-action switching contact 1 NC + 1 NO

ES 508

Slow-action switching contact 1 NC

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose.

Dimension drawing
Dimension drawing
Wiring diagram ES 508
Wiring diagram ES 508
Wiring diagram ES 502 E
Wiring diagram ES 502 E

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 6 A 24 V
AC-12 8 A 250 V
AC-15 6 A 230 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 24V min. 10 mA (applies to station 1 with switching element ES508E)
min. at DC 12V min. 10 mA (applies from station 2 with switching element ES502E)
thermal rated current Ith 8 A

Mechanical values and environment

Approach speed 0.01 ... 40 m/min
Connection type
4 x M25 x 1.5
Number NC contacts 2
Number of switching elements 3
Number of NO contacts 2
Number of positively driven contacts 1
Design upright
Actuating element Chisel plunger (Operating point accuracy ± 0.002. The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Switching principle
Snap-action switching contact (Contact closing time<4 ms, contact bounce time<3 ms, applies from station 2 with switching element ES502E)
Slow-action switching contact (applies to station 1 with switching element ES508E)
Degree of protection IP67
Plunger spacing 16 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10D 20 x 10⁶

Miscellaneous

Additional information Mixed contact assembly (On upright multiple limit switches, it is necessary to start with the safety station/s from the flange side. If several safety stations are to be installed, these must be installed directly one after the other.)

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 2,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 096066
Makale adı GSBF03D16-1508-M
Ağırlık 0,717kg
Gümrük sınıfı 85365019000
ECLASS 27-27-06-02 Multi-position switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.