Series RGBF... 12/16 mm, mechanical

  • Plunger spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
  • LED function display optional
RGBF02B12-514-MC2085 (Sip. No. 095286)

Açıklama

Switching element

ES 514

Snap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose.

LED function display

Function displays are available for the following voltage ranges (see accessories)

LE024ge

24 V DC (for ES 514)

LE060

12 ... 60 V AC/DC

LE110

110 V AC ±15%

LE220

220 V AC ±15%

Dimension drawing
Dimension drawing
Wiring diagram ES514
Wiring diagram ES514

Dimensional drawings

Dimensional drawings
*Safety switching element ES 514 positive opening. Positive opening function is dependent on maintaining this distance. Actuators (dogs) must be connected to the machine in a flush position.
1Operating point
1)Pressure sensitive label 041734 applied.
2Free position
3Groove with sealing ring
4LE024GE
5Number of plungers
6Switch can be replaced only with the same type.
7Ball bearings

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Connection cross section 0.34 ... 1.5 mm²
Display module
DC 21.6 ... 24 ... 26.4 V LED yellow
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Utilization category
DC-13 6 A 24 V
AC-15 2.5 A 230 V
Short circuit protection according to IEC 60269-1 6A gG
Switching current
min. at DC 24V min. 5 mA
thermal rated current Ith 10 A

Mechanical values and environment

Approach speed 0.01 ... 120 m/min
Connection type 4 x M25 x 1.5
Number of switching elements 2
Number of NO contacts 2
Number of positively driven contacts 2
Design upright, according to DIN 43697
Actuating element Roller plunger (Ball bearings)
Actuating force min. 25 N
Installation orientation any
Mechanical life 1 x 10⁶
Contact bounce time ≤ 3ms
Roller diameter 8
Switching principle Snap-action switching contact
Contact closing time max. 5 ms
Degree of protection IP67
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10D 2 x 10⁶

Miscellaneous

C number
C2085

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 2,4 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 095286
Makale adı RGBF02B12-514-MC2085
Ağırlık 0,73kg
Gümrük sınıfı 85365019000
ECLASS 27-27-06-02 Multi-position switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.