EUCHNER – More than safety.
EUCHNER – More than safety.

STA3A-4141A024SEM4AS1C1993 (Sip. No. 119732)

STA ASi safety switch, plug connector(s) M12, escape release

  • AS-Interface
  • Plug connector(s) M12, 4-pin
  • Auxiliary release
  • Escape release, long
  • Closed-circuit current principle
STA3A-4141A024SEM4AS1C1993 (Sip. No. 119732)

Açıklama

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel with horizontal approach direction

If increased play is required when the door is closed, an actuator with overtravel is available. This actuator allows the door to move slightly in the actuating direction when closed. This is important, for example, if safety doors have a rubber buffer as an end stop. An actuator with overtravel can reduce the permanent pressure of the compressed rubber buffer. This reduces the load on both the switch head and the door mechanism.

Guard locking principle

closed-circuit current (power to unlock): In a safety guard with guard locking according to the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with current. The guard is unlocked by means of magnetic force. This is also referred to as mechanical guard locking.

Control of the guard locking solenoid

The guard locking solenoid is controlled via AS-Interface bit D0. In order to achieve safe control of the guard locking, the auxiliary voltage must also be switched safely.

auxiliary voltage

The ASi auxiliary voltage is required to supply the guard locking solenoid.

AS-Interface inputs

D0, D1

Monitoring of the guard position

D2, D3

Monitoring the guard locking

AS-Interface outputs

D0

Activating the guard locking

D1

LED red

D2

LED green

LED indicator

The Power LED indicates the operating voltage on the bus.

The Fault LED indicates when an error has been detected on the AS-Interface bus.

The green and red LEDs can be controlled by the control system via the bus as required using bits D1 and D2.

Auxiliary release

The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Required accessories

Actuator is not included in the scope of delivery.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3Escape release, basic position
4Escape release, unlocked position
5Plug connector not aligned

Connection examples

Connection examples
View of plug side

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/5

Electrical connection values

ASI operating current max. 45 mA
ASI data in
according to AS-i Safety at Work D0, D1, D2, D3 (see positively driven contact)
ASI data out
Guard locking solenoid D0 (1 = Solenoid energized)
LED green D2 (1 = LED on)
LED red D1 (1 = LED on)
AS-Interface auxiliary voltage 24 V -15 ... 10 %
Auxiliary current AS-Interface 300 mA
AS-Interface LED
green Power
red Fault
AS-Interface protocol ASi-3
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 22.5 ... 30 ... 31.6 V
Solenoid duty cycle 100 %

Mechanical values and environment

Approach speed max. 20 m/min
Connection type
1 x Plug connector M12 (4-pin)
Number of door position positively driven contacts
according to AS-i Safety at Work
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work 1 D2,D3 (1 = locked)
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 24.5 mm
Mechanical life 1 x 10⁶
Retention force 20 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Alloy - die-cast
Locking force Fmax 3000 N
Locking force FZh 2300 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position1.15x10720 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking1.15x10720 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-S-GT-SN

Overtravel 5 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 5,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 119732
Makale adı STA3A-4141A024SEM4AS1C1993
Ağırlık 0,816kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.