Safety switch TX ASi, plug connector M12 (closed-circuit current principle)
- Auxiliary release on the front
- Plug connector M12
Açıklama
Guard locking type
TX1 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
Control of the guard locking solenoid
The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.
AS-Interface inputs
D0, D1 | Positively driven NC contact 1 (safety door monitor) |
D2, D3 | Positively driven NC contact 2 (guard lock monitoring) |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D1 | LED red |
D2 | LED green |
Internal LED function display
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
External LED function display
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Dimensional drawings
1 | Auxiliary release |
2 | LED indicator |
3 | Locking screw |
Connection examples
View of plug side |
Teknik Veriler
Approvals
Electrical connection values
ASI operating current | max. 45 mA |
ASI data in | |
according to AS-i Safety at Work | D0, D1, D2, D3 (see positively driven contact) |
ASI data out | |
LED green | D2 (1 = LED on) |
Guard locking solenoid | D0 (1 = Solenoid energized) |
LED red | D1 (1 = LED on) |
AS-Interface auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
Auxiliary current AS-Interface | 300 mA |
AS-Interface protocol | ASi-3 |
AS-Interface slave type | ID-Code: B, EA-Code: 7 |
ASI voltage | 22.5 ... 30 ... 31.6 V |
Solenoid duty cycle | 100 % |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
1 x | Plug connector M12 (4-pin) |
Number of door position positively driven contacts | |
according to AS-i Safety at Work | |
Number of guard lock monitoring positively driven contacts | |
according to AS-i Safety at Work | 1 D2,D3 (1 = locked) |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 32 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +50 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Die-cast alloy cathodically dipped |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
In combination with actuator ACTUATOR-X-GNQ
Overtravel | 8 mm |
In combination with actuator ACTUATOR-X-GQ
Overtravel | 1 mm |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Interrupteur de sécurité TX…AS1
Manual de instrucciones Interruptor de seguridad TX…AS1
Betriebsanleitung Sicherheitsschalter TX…AS1
Diğer Belgeler
CAD Verileri
Sipariş verileri
Sip. No. | 094403 |
Makale adı | TX1B-A024SEM4AS1 |
Ağırlık | 0,87kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |