EUCHNER – More than safety.
EUCHNER – More than safety.

TZ1LE024SEM4AS1 (Sip. No. 086140)

Safety switch TZ ASi, plug connector M12 (closed-circuit current principle)

  • Auxiliary release on the front
  • Actuating head fitted left
  • Plug connector M12
TZ1LE024SEM4AS1 (Sip. No. 086140)

Açıklama

Guard locking type

TZ1

Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.

AS-Interface inputs

D0, D1

Door monitoring contact SK

D2, D3

Solenoid monitoring contact ÜK

Evaluation is performed via a safety monitor.

AS-Interface outputs

D0

Guard locking solenoid

D1

LED red

D2

LED green

LED function display

  • The Power LED indicates the operating voltage on the bus.
  • The Fault LED indicates if a fault has been detected on the AS-Interface bus.
  • The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. A seal and auxiliary tool are fitted to protect against tampering.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Plug connector not aligned
aTravel without operation: actuator is in the guide slot, but function is not triggered.
bSwitching operation completed. Actuator must be inserted to this point to ensure safe switching. The actuator must be withdrawn at least to point a for switching off.

Connection examples

Connection examples
View of plug side

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_TZ_ET 24013_ET 24014CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/5Asi Interface_56201_

Electrical connection values

ASI operating current max. 45 mA
ASI data in
according to AS-i Safety at Work D0, D1, D2, D3 (see positively driven contact)
ASI data out
LED red D1 (1 = LED on)
Guard locking solenoid D0 (1 = Solenoid energized)
LED green D2 (1 = LED on)
AS-Interface auxiliary voltage 24 V -15% ... 10 %
Auxiliary current AS-Interface 350 mA
AS-Interface LED
red Fault
green Power
AS-Interface protocol ASi-3
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 22.5 ... 30 ... 31.6 V
Solenoid duty cycle 100 %

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction
Actuating head left C
Connection type
1 x Plug connector M12 (4-pin)
Number of door position positively driven contacts
according to AS-i Safety at Work
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work 1 D2,D3 (1 = locked)
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 52 mm
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -25 ... +55 °C
Material
Housing Anodized die-cast alloy
Contact Silver alloy, gold flashed
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-Z-G

Overtravel 4 mm

In combination with actuator ACTUATOR-Z-GN

Overtravel 16 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 6,5 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 086140
Makale adı TZ1LE024SEM4AS1
Ağırlık 1,199kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.