Transponder-coded safety switches are available both as a guard locking device, as well as an interlocking device of type 4. Unicode and multicode devices are available in both product groups. The interlocking devices feature a particularly compact read head design on the safety door. The guard locking device is a particularly robust solution with a very high locking force that meets PL e due to the integrated transponder technology.Features
- AS-Interface Safety at Work integrated
- Interlocking devices of type 4 with extremely compact read heads
- Metal guard locking devices with very high locking force
- With guard locking devices, both the door position and the locking position are monitored

You will find further information in our product catalog.
Ürün Bulucu
Hızlı Arama
Degree of protection
Escape release
Connection
Guard locking
Ürünler (20)
Sonuç bulunamadı

172238
CES-FD-AS2A-U-01-U002-172238
Field evaluation unit CES-FD-AS2A with ASi connection
CES-FD-AS2A-U-01-U002-172238
Field evaluation unit CES-FD-AS2A with ASi connection
- Connection of a CES read head or CKS Electronic-Key adapter via M8 plug connector(s)
- Evaluation of transponder data
- Integrated ASi connection, permanently connected PUR cable
- Unicode
- Highest safety at category 4 / PL e according to EN ISO 13849-1

120546
CES-I-AS2A-M-C04-SC-120546
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
CES-I-AS2A-M-C04-SC-120546
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
- Very compact design with 3 active faces
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Plug connector M8, 3-pin
- Multicode

120547
CES-I-AS2A-U-C04-SC-120547
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
CES-I-AS2A-U-C04-SC-120547
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
- Very compact design with 3 active faces
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Plug connector M8, 3-pin
- Unicode

165486
CET3-AS-CRA-AB-50X-1-C2290-165486
Safety switch CET-AS – with AS-i connection, closed-circuit current principle, with wire front release (bowden) 4 m
CET3-AS-CRA-AB-50X-1-C2290-165486
Safety switch CET-AS – with AS-i connection, closed-circuit current principle, with wire front release (bowden) 4 m
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Wire front release (bowden), automatic return, rope length 4 m
- Approach direction A (delivery state)

111214
CET3-AS-CRA-AB-50X-SJ-AS1-111214
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CET3-AS-CRA-AB-50X-SJ-AS1-111214
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction A (delivery state)

113631
CET4-AS-CRA-AB-50X-SJ-AS1-113631
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRA-AB-50X-SJ-AS1-113631
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction A (delivery state)

116515
CET4-AS-CRA-CB-50X-1-116515
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRA-CB-50X-1-116515
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach direction A (delivery state)

120008
CET4-AS-CRB-AB-50X-1-120008
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRB-AB-50X-1-120008
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction B (delivery state)

123592
CKS-K-AS2A-U-C20-PC-123592
Key adapter CKS-K-AS with AS-i connection
CKS-K-AS2A-U-C20-PC-123592
Key adapter CKS-K-AS with AS-i connection
- Key adapter with integrated CES read head
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Simple connection via AS-i
- High degree of protection IP67

171319
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode

163976
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Auxiliary release
- Unicode

163977
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode

163972
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Unicode
- Hygienic version

163974
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Unicode
- Hygienic version

166889
CTP-I2-AS2B-U-HA-AZC-SJ-166889
Safety switch CTP-I2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-I2-AS2B-U-HA-AZC-SJ-166889
Safety switch CTP-I2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)

126645
CTP-L1-AS1B-M-HA-AZ-SJ-126645
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CTP-L1-AS1B-M-HA-AZ-SJ-126645
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach directions A, B and C (delivery state)

126644
CTP-L1-AS1B-U-HA-AE-SJ-126644
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12, with escape release (closed-circuit current principle)
CTP-L1-AS1B-U-HA-AE-SJ-126644
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12, with escape release (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- With escape release
- Approach directions A, B and C (delivery state)

124987
CTP-L1-AS1B-U-HA-AZ-SJ-124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CTP-L1-AS1B-U-HA-AZ-SJ-124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)

126646
CTP-L2-AS1B-M-HA-AZ-SJ-126646
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-L2-AS1B-M-HA-AZ-SJ-126646
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach directions A, B and C (delivery state)

124988
CTP-L2-AS1B-U-HA-AZ-SJ-124988
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-L2-AS1B-U-HA-AZ-SJ-124988
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)