Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach direction A (delivery state)
Açıklama
Guard locking type
CET4 | Open-circuit current principle. Guard locking by control of AS-i output 0. Release by spring force. |
Control of the guard locking solenoid
The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0.
AS-Interface inputs
D0, D1 | Door monitoring |
D2, D3 | Guard lock monitoring |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D0 | Guard locking |
D1 | LED red |
D2 | LED green |
LED function display
- The ASI LED indicates the operating voltage on the bus.
- The State LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Dimensional drawings
Connection examples
View of plug side |
Connection examples
Teknik Veriler
Approvals
Electrical connection values
ASI address | 0 |
ASI operating current | 50 mA |
ASI data in | |
according to AS-i Safety at Work | D3 (Guard locking) |
according to AS-i Safety at Work | D1 (Door position) |
according to AS-i Safety at Work | D2 (Guard locking) |
according to AS-i Safety at Work | D0 (Door position) |
ASI data out | |
LED red | D1 (1 = LED on) |
LED green | D2 (1 = LED on) |
Guard locking solenoid | D0 (1 = Solenoid energized) |
AS-Interface auxiliary voltage | 24 V -15 ... 10 % |
Auxiliary current AS-Interface | 480 mA |
AS-Interface LED | |
green | Power |
red | Fault |
AS-Interface protocol | ASi-3 |
AS-Interface slave type | ID-Code: B, EA-Code: 7 |
ASI voltage | 22.5 ... 30 ... 31.6 V |
Safety class | III |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
1 x | Plug connector M12 (4-pin) |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Mechanical life | 2 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 (When inserted and secured) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Ramp | Stainless steel |
Safety switch housing | Die-cast aluminum |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N (FZH = FMAX/1.3) |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of guard locking | PL e | - | 3.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Aksesuar
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Diğer Belgeler
Sipariş verileri
Sip. No. | 116515 |
Makale adı | CET4-AS-CRA-CB-50X-1-116515 |
Ağırlık | 1,247kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |