CTP-L2-AS1B-U-HA-AZ-SJ-124988 (Sip. No. 124988)

Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 3,900 N
  • Category 4 / PL e according to EN ISO 13849-1
  • Unicode
  • Approach directions A, B and C (delivery state)
CTP-L2-AS1B-U-HA-AZ-SJ-124988 (Sip. No. 124988)

Açıklama

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking type

CTP‑L2

Guard locking actuated by power-ON and released by spring force (open-circuit current principle).

Control of the guard locking solenoid

The guard locking solenoid can be controlled via AS-Interface bus bit D0 or via the auxiliary power.

AS-Interface inputs

D0, D1

Door monitoring

D2, D3

Guard lock monitoring

Evaluation is performed via a safety monitor.

AS-Interface outputs

D0

Guard locking

LED function display

  • The ASI LED indicates the state of the ASi bus.
  • The STATE LED indicates the state of the switch.
  • The LOCK/DIA LED indicates if the door is locked and whether a fault has been detected in the switch.
Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Wiring diagram
Wiring diagram
CTP at a glance

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LEDs
4Plug connector not aligned

Connection examples

Connection examples
View of plug side

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_CTP_ET 22017_ET 22018c_UL_us_E155795_3/11Asi Interface_126001_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

ASI data out D0 = Control of guard locking
ASI operating current 50 mA
ASI data in
according to AS-i Safety at Work D1 (Door position)
according to AS-i Safety at Work D2 (Guard locking)
according to AS-i Safety at Work D3 (Guard locking)
according to AS-i Safety at Work D0 (Door position)
AS-Interface auxiliary voltage 24 V -15 ... 10 %
Auxiliary current AS-Interface 400 mA
AS-Interface protocol ASi-3
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 26.5 ... 30 ... 31.6 V
Safety class III

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M12, 4-pin
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67/IP69/IP69K (When inserted and secured)
Ambient temperature -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch head cover Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-4.1x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 3,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 124988
Makale adı CTP-L2-AS1B-U-HA-AZ-SJ-124988
Ağırlık 0,592kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.