AnasayfaProductsTransponder-coded key systems EKS and CKSElectronic-Key-System EKSRead station for safe applications EKS Light FSA modular
Electronic-Key adapter EKS Light FSA modular
Electronic-Key-System EKS Light
EKS Light is optimized for quick, straightforward integration into a control system environment. For this purpose, the Electronic-Key has a pre-defined data structure that is evaluated directly by the read-only station.With EKS Light, you therefore procure not just the EKS hardware, but an integrated solution for managing user groups (who is allowed to access what?) and access levels (what is the user allowed to do?).
For this purpose, the data structure on the Electronic-Key and the evaluation electronics in the read-only station form a closed system with user group identification and up to 16 access levels that can be used directly for a suitable application.
The complete evaluation logic for Electronic-Key detection is already integrated into the device and therefore does not need to be programmed into a control system. The device first determines whether the Electronic-Key read is valid and access to the machine is authorized. If this is the case, the access level is determined and transferred to the control system via the 4-bit parallel interface. The authorization for a specific machine function must be assigned in the control system for each access level detected; the machine function is enabled in this way.
Benefits for you
- Safe, controlled access to your processes
- Automatic logging on and logging off by placing the Electronic-Key
- Variety of possible applications in all sectors due to industrial housing
- Straightforward integration due to 4-bit parallel interface
- Increased product quality due to controlled manufacture
- Increased reliability of your installations and as a result lower production costs
Modular design
With the modular design, the Electronic-Key adapter and electronics are mounted physically separated. Due to the separation, the Electronic-Key adapter fits in standard mounting bores with Ø 22.5 mm. The rounded shape of the Electronic-Key adapter and the FDA-approved plastic permit use in hygienically sensitive areas. With this design, the Electronic-Key is only held in front or dropped into place.- Electronic-Key adapter mounted physically separated from the electronics
- Straightforward installation in standard mounting bore Ø 22.5 mm
- Suitable for hygienic areas
- Very robust housing for use in extremely harsh environments
Version FSA
The FSA devices also have a second, redundant channel, which is generally available in the form of an additional semiconductor switching contact. This switching contact is used with functionally safe applications.The Electronic-Key-System EKS is a transponder-based read/write system for industrial use. It is used primarily for electronic access control and access management as an alternative to the normal, password-based systems. Due to the combination of Electronic-Key and information memory, however, it offers much more than just a password replacement. As an open, freely configurable system with various data interfaces, EKS is of very universal application.
For operation, the Electronic-Key is placed into the Electronic-Key adapter. The data are transferred between the Electronic-Key and the read/write station without using any contacts. In a further step, the data are transferred to a control system. The owner of the Electronic-Key is identified and the user rights are transferred during this process, for example. Depending on the EKS system, further information can be saved on the Electronic-Key and transferred. These data can be used to control specific functions or contain encrypted process parameters for an installation, for example.
You will find further information in our product catalog and flyer.
For operation, the Electronic-Key is placed into the Electronic-Key adapter. The data are transferred between the Electronic-Key and the read/write station without using any contacts. In a further step, the data are transferred to a control system. The owner of the Electronic-Key is identified and the user rights are transferred during this process, for example. Depending on the EKS system, further information can be saved on the Electronic-Key and transferred. These data can be used to control specific functions or contain encrypted process parameters for an installation, for example.
You will find further information in our product catalog and flyer.
Ürünler (4)
Sonuç bulunamadı
113645
EKS-A-APRA-G08
Interface adapter EKS Light FSA modular (supports all operating states)
EKS-A-APRA-G08
Interface adapter EKS Light FSA modular (supports all operating states)
- Interface adapter with 4-bit parallel interface
- Use in conjunction with Electronic-Key adapter FHM
- A complete read-only system consists of an Electronic-Key adapter FHM and a modular interface adapter
- Simple connection
- Read-only system
- Internal evaluation of the data from the Electronic-Key
- Output of the access level via 4-bit parallel interface
- Has all operating states
- Connection to PLC
- Version FSA (For Safety Applications)
106585
EKS-A-SFH-G30-2000
EKS Electronic-Key adapter FHM, with flying lead
EKS-A-SFH-G30-2000
EKS Electronic-Key adapter FHM, with flying lead
- Small design for installations where there is little space
- Installation in standard assembly hole Ø 22.5 mm
- Closed design, rounded contours for hygienic areas
- Plastic with high resistance to media
- IP69K
- Cable, 2 m, with flying lead
158353
EKS-A-SFH-G30-3000
EKS Electronic-Key adapter FHM, with flying lead
EKS-A-SFH-G30-3000
EKS Electronic-Key adapter FHM, with flying lead
- Small design for installations where there is little space
- Installation in standard assembly hole Ø 22.5 mm
- Closed design, rounded contours for hygienic areas
- Plastic with high resistance to media
- IP69K
- Cable 3 m with flying lead
116118
EKS-A-SFH-G30-ST150
EKS Electronic-Key adapter FHM, with M8 male plug
EKS-A-SFH-G30-ST150
EKS Electronic-Key adapter FHM, with M8 male plug
- Small design for installations where there is little space
- Installation in standard assembly hole Ø 22.5 mm
- Closed design, rounded contours for hygienic areas
- Plastic with high resistance to media
- IP69K
- Cable, 0.13 m, with M8 male plug
- IMPORTANT: The connecting cable to the EKS interface adapter is not included with key adapter FHM and must be ordered separately.