Evaluation unit CES-AZ-AES-02B (for 2 read heads)
- 2 read heads can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Unicode
- Plug-in connection terminals
- Category 4 / PL e according to EN ISO 13849-1
Açıklama
Unicode evaluation
Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
New actuators are taught-in by fitting a jumper.
Guard lock monitoring
Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories
Category according to EN ISO 13849-1
Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
- Category 4 / PL e according to EN ISO 13849-1
Each safety path is independently safe.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Safety output status |
Additional connections
TST | Input for self-test |
O1, O2 | Monitoring outputs (semiconductor) |
DIA | Diagnostic output |
Y1, Y2 | Feedback loop |
J1, J2 | Teach-in input |
S | Start button connection (monitoring of the falling edge) |
Important: The plug-in connection terminals are not included and must be ordered separately.
Dimensional drawings
1 | Suitable for 35 mm mounting rail according to EN 60715 |
Connection examples
Teknik Veriler
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | max. 10 % |
Operating and display elements
LED display | |
Status LED | |
Safety contacts status | |
Diagnostics LED |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
Connection cross section | |
Plug-in screw / spring terminals | 0.25 ... 2.5 mm² |
Operating voltage DC | |
UB | 21 ... 24 ... 27 V DC regulated, residual ripple<5% |
EMC protection requirements | Acc. to EN 60947-5-3 |
Current consumption | |
(with relay energized) | 150 mA (without taking into account the load currents at the monitoring outputs) |
Current via feedback loop | 5 ... 8 ... 10 mA |
Degree of contamination (external, according to EN 60947-1) | 2 |
permissible resistance in feedback loop | max. 600 Ω |
Inputs: start button S, test input TST | |
Input voltage | |
HIGH | 15 ... UB V DC |
LOW | 0 ... 2 V DC |
Input current | |
HIGH | 5 ... 8 ... 10 mA |
Monitoring outputs: diagnostics DIA, door monitoring outputs O1,O2 | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 20 mA |
Safety contacts 13/14, 23/24 | |
Fuse | |
external (safety circuit) according to EN 60269-1 | 6 AgG or 6 A circuit breaker (characteristic B or C) |
Output type | Relay contacts, floating |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Discrepancy time | |
(between the operating points of both relays) | max. 25 ms |
Utilization category | |
DC-12 | 60 V 0.3 A |
DC-13 | 24 V 3 A |
DC-12 | 30 V 6 A |
AC-15 | 230 V 2 A |
AC-12 | 60 V 0.3 A |
AC-12 | 30 V 6 A |
Switching load | |
according to c UL us | Class 2 max. 30 V AC / Class 2 max. 60V DC |
Switching current | |
at switching voltage AC/DC 5 ... 30 V | 10 ... 6000 mA |
at switching voltage AC 5 ... 230 V | 10 ... 2000 mA |
at switching voltage AC/DC 21 ... 60 V | 1 ... 300 mA |
Mechanical values and environment
Connection type | plug-in connection terminals, coded (Terminals not included) |
Number of read heads | max. 2 read heads can be connected |
Ready delay | 10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.) |
Switching frequency | max. 0.25 Hz (In case of monitoring with feedback loop, the actuators must remain outside the actuating range, e.g. with a door open, until the feedback loop is closed.) |
Atmospheric humidity | |
not condensing | max. 80 % rH |
Mounting distance | |
between evaluation units | min. 10 mm |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Response time | |
after change in the actuation status, 2 active actuators | max. 290 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 430 ms. After brief actuation |
Start button response delay (for Manual start operating mode) | 200 ... 300 ms |
after change in the actuation status, 1 active actuator | max. 210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 430 ms. After brief actuation |
Start button actuating duration (for Manual Start operating mode) | min. 250 ms |
Degree of protection | IP20 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Dwell time | min. 3 s (The dwell time is the time that the actuator must be outside the actuating range.) |
Material | |
Housing | Plastic PA6.6 |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 Relay with internally monitored contacts |
Mechanical life | |
Operating cycles (relay) | 10 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Number of switching cycles | |
≤ 0.1 A at 24 V DC | max. 760000 1/y |
≤ 3 A at 24 V DC | max. 34600 1/y |
≤ 1 A at 24 V DC | max. 153000 1/y |
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Monitoring of the guard position | |
Category | 4 (This value is dependent on the number of switching cycles and the switching current.) |
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 1.9 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Safety contacts 13/14, 23/24 | |
Number of switching cycles | |
≤ 0.1 A at 24 V DC | max. 760000 1/y |
≤ 1 A at 24 V DC | max. 153000 1/y |
≤ 3 A at 24 V DC | max. 34600 1/y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294, CES-A-LNN-25V-115107 and actuator CES-A-BBN-106600
Switch-on distance | |
in z direction (with center offset x,y=0), in x direction (with center offset y,z=0) | 15 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | |
in y direction | max. 100 mm |
in x or z direction | max. 50 mm |
Secured switching distance sao | |
in z direction (with center offset x,y=0), in x direction (with center offset y,z=0) | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | 1 ... 4 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LMN-SC
Mounting distance | |
between read heads | min. 20 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s | |
Minimum distance | min. 1.2 mm |
Switch-on distance | |
with center offset m=0 | 5 mm (These values apply to surface installation of the read head in steel.) |
Secured switch-off distance sar | max. 10 mm |
Secured switching distance sao | |
with center offset m=0 | min. 3.5 mm (These values apply to surface installation of the read head in steel.) |
Switching hysteresis | 0.1 ... 0.3 mm (These values apply to surface installation of the read head in steel.) |
In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840
Switch-on distance | |
with center offset m=0 | 8 mm A distance of s = 3 mm must be maintained for a side approach direction. (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Secured switch-off distance sar | |
with center offset m=0 | max. 25 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Secured switching distance sao | |
with center offset m=0 | min. 5 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Switching hysteresis | |
with center offset m=0 | 1 ... 1.8 mm (These values apply to surface installation of the read head in metal and non-metallic installation of the actuator.) |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294, CES-A-LNN-25V-115107 and actuator CES-A-BDN-06-104730
Switch-on distance | |
in z direction (with center offset x,y=0), in x direction (with center offset y,z=0) | 19 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | |
in y direction | max. 100 mm |
in x or z direction | max. 50 mm |
Secured switching distance sao | |
in z direction (with center offset x,y=0), in x direction (with center offset y,z=0) | min. 14 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | 4 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm (on mounting in non-metallic environment) |
Switch-on distance | |
with center offset m=0 | 16 mm (on mounting in non-metallic environment) |
Secured switch-off distance sar | max. 33 mm |
Secured switching distance sao | |
with center offset m=0 | min. 11 mm (on mounting in non-metallic environment) |
Switching hysteresis | 0.5 ... 2 mm (on mounting in non-metallic environment) |
In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294, CES-A-LNN-25V-115107
Mounting distance | |
between read heads | min. 160 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Switch-on distance | |
for vertical approach direction (center offset m=0) | 23 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 10 mm) | +/- 28 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 60 mm |
Secured switching distance sao | |
for side approach direction (distance in x direction 10 mm) | min. +/- 24 mm (These values apply to surface installation of the read head and the actuator.) |
for vertical approach direction (center offset m=0) | min. 16 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
for side approach direction (distance in x direction 10 mm) | 1 ... 1.3 mm (These values apply to surface installation of the read head and the actuator.) |
for vertical approach direction (center offset m=0) | 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20
Switch-on distance | |
with center offset m=0 | 9 mm A distance of s = 4 mm must be maintained for a side approach direction. (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Secured switch-off distance sar | |
with center offset m=0 | max. 26 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.) |
Switching hysteresis | |
with center offset m=0 | 1 ... 1.8 mm (These values apply to surface installation of the read head in metal and non-metallic installation of the actuator.) |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance | |
between read heads | min. 50 mm |
In combination with read head CES-A-LQA-SC
Mounting distance | |
between read heads | min. 80 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935
Actuator distance s | |
Minimum distance for side approach direction | min. 5 mm |
Switch-on distance | |
with center offset m=0 | 16 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 32 mm |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
with center offset m=0 | 0.5 ... 1.4 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Switch-on distance | |
for vertical approach direction (center offset m=0) | 15 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 8 mm) | +/- 22 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 47 mm |
Secured switching distance sao | |
for side approach direction (distance in x direction 8 mm) | min. +/- 18 mm (These values apply to surface installation of the read head and the actuator.) |
for vertical approach direction (center offset m=0) | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
for vertical approach direction (center offset m=0) | 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.) |
for side approach direction (distance in x direction 8 mm) | 1 ... 1.8 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935
Actuator distance s | |
Minimum distance for side approach direction | min. 3 mm |
Switch-on distance | |
with center offset m=0 | 9 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 21 mm |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | |
with center offset m=0 | 0.5 ... 1 mm (These values apply to surface installation of the read head and the actuator.) |
In combination with read head CES-A-LSP-05V-104966 and actuator CES-A-BSP-104970
Switch-on distance | |
with center offset m=0 | 20 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.) |
Secured switch-off distance sar | max. 45 mm |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.) |
Switching hysteresis | 1 ... 4 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.) |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
Minimum distance for side approach direction | min. 3 mm |
Switch-on distance | |
with center offset m=0 | 15 mm (These values apply to surface installation of the read head and the actuator.) |
Secured switch-off distance sar | max. 26 mm |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm (These values apply to surface installation of the read head and the actuator.) |
Switching hysteresis | 0.5 ... 2 mm (These values apply to surface installation of the read head and the actuator.) |
Aksesuar
CEM-A-LE05K-S2
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
CEM-A-LE05K-S1-10P
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With remanence
- CES evaluation unit connection: 10 m cable, PUR
- Connection for solenoid operating voltage: M8 male plug
- Up to category 4 according to EN ISO 13849-1
CET1-AX-LRA-00-50X-SA
- Read head with guard locking
- Locking force up to 6500 N
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- 2 LEDs (1 freely configurable)
- Approach direction A (delivery state)
CET1-AX-LRA-00-50X-SF
- Read head with guard locking
- Locking force up to 6500 N
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12 (can be rotated by 360°)
- 2 LEDs (1 freely configurable)
- Approach direction A (delivery state)
CKS-A-L1B-SC-113130
- Key adapter with integrated CES read head
- Simple connection via plug connector M8
- Front cover: red
- High degree of protection IP67
- LED indicator
CKS-A-L1B-SC-158081
- Key adapter with integrated CES read head
- Simple connection via plug connector M8
- Front cover: black
- High degree of protection IP67
- LED indicator
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Diğer Belgeler
CAD Verileri
Sipariş verileri
Sip. No. | 104775 |
Makale adı | CES-AZ-AES-02B |
Ağırlık | 0,299kg |
GTIN | 4047048005662 |
Gümrük sınıfı | 85364110 |
ECLASS | 27-27-24-03 Safety-related transponder switch |