CKS2-K-BP-CC-FLX-F00-USI-168631 (Sip. No. 168631)

Key adapter CKS2-K-BP with FlexFunction

  • Key adapter with integrated evaluation electronics
  • Suitable for separate operation (no series connection)
  • 2 safety outputs (semiconductor outputs)
  • Short circuit monitoring
  • Category 4 / PL e according to EN ISO 13849-1
  • LED indicator, multi-color RGB
  • M12 plug connector, 5-pin, connecting cable, 15 cm
  • Direct connection to IP67 field modules
  • Pushbutton for teach-in operation
  • Mechanical detent mechanism for inserted key
CKS2-K-BP-CC-FLX-F00-USI-168631 (Sip. No. 168631)

Açıklama

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

Key evaluation

EUCHNER products with FlexFunction require a teach-in operation during setup to configure the device. The device’s function depends on the taught-in key type.

Important: Keys must be ordered separately!

Terminal assignment

PinDesignationFunction
1UBPower supply, DC 24 V
2FO1ASafety output, channel A
30 VGround, DC 0 V
4FO1BSafety output, channel B
5-n.c.
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LED
2Rubber seal
3Pushbutton

Connection examples

Connection examples

Teknik Veriler

Approvals

FCC_CKS2_2AJ58-17c_UL_us_E346349_1/1

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 100 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3 max. 125 ms
Safety class III
Current consumption 40 mA
Degree of contamination (external, according to EN 60947-1) 2
Safety outputs FO1A/ FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-4V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time max. 10 ms
Switching current
per safety output 1 ... 150 mA
Test pulse duration 0.3 ms
Test pulse interval 97 ... 105 ms

Mechanical values and environment

Ready delay 2 s
Installation orientation on the front
Storage temperature -30 ... +70 °C
Mounting cut-out 33 x 68 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection
in mounted condition (only access side) IP65/IP67 (When installed)
Ambient temperature
for UB= 24 V DC -30 ... +55 °C
Material
Connecting cable PUR
Housing Plastic PA6-GF30 black
Connection X1
Connection type Connecting cable with plug connector M12
Static bending radius 5x cable diameter
Cable outlet straight
Cable length 0.15 m
Number of pins 5

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Safe key detectionPL e34.11x10-9420 y


Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 168631
Makale adı CKS2-K-BP-CC-FLX-F00-USI-168631
Ağırlık 0,19kg
Gümrük sınıfı 85389099990
ECLASS 27-27-24-03 Safety-related transponder switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.