Safety switch CTM-BR
Benefits for you
- Communicating safety switch with guard locking and safe guard lock monitoring
- Possible to connect up to 20 safety switches in series
- Industry 4.0 ready
- Integrated short circuit monitoring by pulsing
- Two safe semiconductor outputs
- Safety category 4 and PL e according to EN ISO 13849-1
Industry 4.0 ready
The switch can communicate in combination with an EUCHNER IO-Link Gateway, and sends process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.Function
Thanks to the transponder technology, even a single CTM achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideal for applications requiring a high performance level in a confined space.Versatile use
The CTM reliably secures small safety doors and flaps on machines and systems. Thanks to the integrated guard locking and guard lock monitoring, it can be used both for process protection and the protection of personnel.The compact design permits space-saving mounting on the guard. The very robust plastic housing and the high degree of protection IP65/IP67/IP69/IP69K make the CTM the all-rounder for almost every industrial use.
With its smooth surfaces, rounded edges, and materials resistant to cleaning agents, the CTM is particularly suitable for use in the food and packaging industries.
Mounting and principle of operation
The CTM consists of two components, a safety switch and a separate actuator. The safety switch is mounted on the fixed part of the guard, the actuator on the movable part. The compact dimensions (120 mm x 36 mm x 25 mm) permit simple integration into any machine design.Door pivoting radii as small as 150 mm are possible thanks to the innovative ball actuator. The integral adhesive force (25/50 N) effectively prevents doors from being opened when they are not locked. When the guard is closed, the actuator moves into the opening of the safety switch.
The safety outputs are switched on if the integrated transponder chip in the actuator is detected and the guard locking activated. Thanks to the integrated prevention of inadvertent locking position (faulty closure protection), unintentional activation of the safety outputs is prevented if the actuator is not completely inserted into the guard locking opening.
Diagnostic information
The safety switches of series CTM can forward comprehensive diagnostic information to the control system. The devices supply process-relevant parameters in real time. They even provide information on preventive maintenance. The sensors measure relevant parameters in the surroundings to indicate problems before a machine failure can occur. In combination with the IO-Link Gateways GWY-CB and ESM-CB, this information is polled from every switch and provided to the control system via IO-Link.Series connection
Series connection in the control cabinet:Wiring takes place in the control cabinet. All information about the status of individual CTMs can be forwarded directly to the control system.
Series connection in the field:
For field wiring, EUCHNER offers the option of using M12 plugs and Y-distributors to connect together several CTMs.
Instead of the Y-plug connectors, it is also possible to use a passive distribution module. On this device, all safety and status signals are collected together in the field and forwarded to the control system using one cable.
Ürünler (19)
Sonuç bulunamadı
174747
CTM-I2-BR-M-ZZ-SA-P-174747
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-M-ZZ-SA-P-174747
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
168250
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
168251
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166870
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
167789
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
173223
CTM-L2-BR-M-ZZ-V15-P-173223
Transponder-coded safety switch CTM-L2-BR, connection cable, flying lead
CTM-L2-BR-M-ZZ-V15-P-173223
Transponder-coded safety switch CTM-L2-BR, connection cable, flying lead
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Connection cable, connecting cable, 15m, flying lead
- Multicode
- Hygienic version
168866
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Series connection possible
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
165517
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166588
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
166092
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 12-pin
- Auxiliary release
- Multicode
168651
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic version
161638
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
161639
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
167795
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
166091
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 12-pin
- Auxiliary release
- Unicode
168249
CTM-LBI-BR-U-AZ-V05-168249
Transponder-coded safety switch CTM-LBI-BR, connecting cable with flying lead
CTM-LBI-BR-U-AZ-V05-168249
Transponder-coded safety switch CTM-LBI-BR, connecting cable with flying lead
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Connecting cable, 5 m, flying lead
- Auxiliary release
- Unicode
161496
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version
161640
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version
167796
CTM-LBI-BR-U-ZZ-V05-P-167796
Transponder-coded safety switch CTM-LBI-BR, connecting cable with flying lead
CTM-LBI-BR-U-ZZ-V05-P-167796
Transponder-coded safety switch CTM-LBI-BR, connecting cable with flying lead
- Series connection possible
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Connecting cable, 5 m, flying lead
- Unicode
- Hygienic version