EUCHNER – More than safety.
EUCHNER – More than safety.

CTM-L2-BR-M-ZZ-SA-P-167789 (Sip. No. 167789)

Transponder-coded safety switch CTM-L2-BR, M12

  • Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
  • Series connection possible
  • Open-circuit current principle
  • Category 4 / PL e according to EN ISO 13849-1
  • Actuation/extension/retention force: 35/30/15 N
  • Plug connector M12, 8-pin
  • Multicode
  • Hygienic version
CTM-L2-BR-M-ZZ-SA-P-167789 (Sip. No. 167789)

Açıklama

Multicode evaluation

Every suitable actuator is detected by the switch.

Guard locking type

CTM‑L2

Guard locking actuated by power ON and released by spring force (open-circuit current principle)

series connection

Safety switches in the CTM-...-BR version can be integrated into a BR device chain. Further information on series connection can be found in the operating instructions for the device.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1FI1BEnable input, channel BWH
2UBElectronics and solenoid operating voltage, 24 V DCBN
3FO1ASafety output, channel AGN
4FO1BSafety output, channel BYE
5OD/CDoor position monitoring output/communicationGY
6FI1AEnable input, channel APK
70VUBElectronics and solenoid operating voltage, 0 V DCBU
8IMPSolenoid control input 24 V DCRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2Active read head face

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-07_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.7 ... 8 A
Power consumption
at max. switching frequency 3 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Turn-on time max. 500 ms
Solenoid duty cycle 100 %
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load DC 24V, UL Class 2 (alternatively, see operating instructions)
Safety class III
Test pulse duration max. 0.3 ms
Test pulse interval 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Solenoid IMP
Input voltage
Guard locking not active (open) 0 ... 5 V DC
Guard locking active (closed) 20.4 ... 26.4 V DC
Current consumption
Guard locking active (closed) 20 ... 50 mA
Door position monitoring output/communication OD/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety input
Current consumption max. 7 mA Safety inputs Fl1A/Fl1B
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Turn-on time max. 400 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3
Single device max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Electrical switching frequency max. 0.25 Hz
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval 100 ms
Operating voltage UB
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Current consumption
IUB at operating voltage UB = 24 V max. 500 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type Plug connector M12, 8-pin
Extraction force 30 N
Ready delay 5.5 s
Actuating force 35 N
Installation orientation any
Switching frequency max. 0.25 Hz
Mechanical life 1 x 10⁶
Overtravel 2 mm
Retention force 15 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +60 °C
Material
Seals Fluorinated rubber (FKM)
Safety switch housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e34.11x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,0 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 167789
Makale adı CTM-L2-BR-M-ZZ-SA-P-167789
Ağırlık 0,26kg
Gümrük sınıfı 85365019
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.