CTP-L2-AP-U-HA-AZ-SH-123370 (Sip. No. 123370)

Transponder-coded safety switch CTP-AP, M23

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
CTP-L2-AP-U-HA-AZ-SH-123370 (Sip. No. 123370)

Açıklama

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L2

Guard locking actuated by power-ON and released by spring force (open-circuit current principle).

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPOperating voltage of guard locking solenoid, 24 V DCVT
2-n.c.RD
3-n.c.GY
4FO1ASafety output, channel 1RD/BU
5FO1BSafety output, channel 2GN
6UBOperating voltage of AP electronics, 24 V DCBU
7RSTReset inputGY/PK
8ODDoor monitoring outputGN/WH
9OIDiagnostic outputYE/WH
10OLGuard lock monitoring outputGY/WH
11-n.c.BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13-n.c.PK
14-n.c.BN/GY
15-n.c.BN/YE
16-n.c.BN/GN
17-n.c.WH
18IMMGuard locking solenoid operating voltage, 0 VYE
190 V UBAP electronics operating voltage, 0 VBN
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CTP at a glance

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LEDs

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_CTP_ET 22017_ET 22018c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IIMP 400 mA
IUB 40 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD, OI, OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-4.1x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 12,6 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 123370
Makale adı CTP-L2-AP-U-HA-AZ-SH-123370
Ağırlık 0,56kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.