Safety switch CTS-BP
Benefits for you
- Communicating safety switch with guard locking
- Safety category 4 and PL e according to EN ISO 13849-1
- Industry 4.0 ready
- FlexFunction device: actuator configures guard lock monitoring and the coding level.
Function
Thanks to the transponder technology, even a single CTS achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideally suited to applications in which compact switch dimensions and a locking force of up to 3,900 N are required.Industry 4.0 ready
The switch can communicate in combination with an EUCHNER IO-Link Gateway, and sends process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.Versatile use
The CTS reliably secures safety doors and flaps on machines and installations. It is suitable for both process protection and the protection of personnel. Thanks to three different mounting orientations and its compact design, the CTS is flexible in use. Optional accessories, such as the retrofittable escape release, enables the CTS to be adapted to every application.The new design with RGB LEDs enables diagnostics visible from three sides and extensive status information and error messages.
FlexFunction
Safety switch CTS is a FlexFunction device combining various functions in a single device. Selecting the actuator defines the function selection. This allows the switch to be configured with or without guard locking monitoring and coded with a high or low coding level.Mounting and principle of operation
The CTS consists of two components: a safety switch and a separate actuator. The safety switch is mounted on the fixed part of the guard, the actuator on the movable part.The actuator is supported on a floating bearing, enabling it to tolerate vibrations or offset. It is suitable for hinged or sliding doors and can be used for small door radii as well.
Ürünler (10)
Sonuç bulunamadı
172870
CTS-C1-BP-CC-FLX-AP-USA-172870
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-USA-172870
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connection cable, connecting cable, PUR, 25 cm, plug connector(s) M12, 8-pin
- Monitoring outputs guard locking and door position 1
172474
CTS-C1-BP-CC-FLX-AP-VBB-172474
Transponder-coded safety switch CTS-C1-BP with FlexFunction, 2 x M12
CTS-C1-BP-CC-FLX-AP-VBB-172474
Transponder-coded safety switch CTS-C1-BP with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
173730
CTS-C1-BP-CC-FLX-AP-VBB-173730
Transponder-coded safety switch CTS-C1-BP with FlexFunction, 2 x M12
CTS-C1-BP-CC-FLX-AP-VBB-173730
Transponder-coded safety switch CTS-C1-BP with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connection to decentralized peripheral systems (e.g. ET200pro) via Y-distributor
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
- Monitoring output door position 1 / guard locking
167917
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 1
169052
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs door position 1 / guard locking and escape release
171593
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Closed-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 2
174157
CTS-C2-BP-CC-FLX-AP-USA-174157
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
CTS-C2-BP-CC-FLX-AP-USA-174157
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Connection cable, connecting cable, PUR, 25 cm, plug connector(s) M12, 8-pin
- Monitoring outputs guard locking and door position 1
172475
CTS-C2-BP-CC-FLX-AP-VBB-172475
Transponder-coded safety switch CTS-C2-BP with FlexFunction, 2 x M12
CTS-C2-BP-CC-FLX-AP-VBB-172475
Transponder-coded safety switch CTS-C2-BP with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
173731
CTS-C2-BP-CC-FLX-AP-VBB-173731
Transponder-coded safety switch CTS-C2-BP with FlexFunction, 2 x M12
CTS-C2-BP-CC-FLX-AP-VBB-173731
Transponder-coded safety switch CTS-C2-BP with FlexFunction, 2 x M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Connection to decentralized peripheral systems (e.g. ET200pro) via Y-distributor
- Connecting cable, PVC, 25 cm, plug connector 2 x M12
- Monitoring output door position 1 / guard locking
169051
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
- Up to category 4 / PL e according to EN ISO 13849-1
- Guard locking suitable for process protection only
- Open-circuit current principle
- Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
- Monitoring outputs guard locking and door position 1